Summit WM3600 Wireless LAN Controller Installation Guide 13
Fan LED
Temperature Status LED
Green Solid Amber Blinking No License to adopt Access Points
or
No Country Code configured on the
controller
or
License and Country Code configured, but
no APs adopted
Fan LED Event
Off System Off / POST Start
Green Blinking POST in Process
Green Solid All System Fans Normal Operation
Amber Solid Redundant Cooling Failure
System Operational
Amber Blinking System Cooling Failure
System will be held in reset until the issue
is resolved
Temperature LED Event
Off System Off
Green Solid Ambient Inlet Temperature is within
specified operating limit
Amber Solid Ambient Inlet Temperature is near the
maximum operating temperature
During controller start up this LED will be
lit Solid Amber. This is normal behavior
and does not indicate an error.
Amber Blinking Ambient Inlet Temperature is above the
maximum specified operating temperature
System will be held in reset until the issue
is resolved