Specifications

Summit WM Controller diagnostics
Summit WM Technical Reference Guide, Software Version 5.374
SNMP Alarms are generated for each of the conditions corresponding to Major and Critical logs.
Summit WM Controller WM200/2000 protocols
The Summit WM software uses several protocols. All the protocols are IP based protocols, and as a
result have corresponding TCP and UDP ports associated with them. You must note the TCP/UDP
ports that are required for the proper functioning of the Summit WM Controller and the Wireless APs.
The following table specifies the protocol ports:
MCE failure. Backup sectors
exhausted.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 7
Contact Technical
Support to arrange
replacement.
NPE Initialization Failure.
Firmware self test (BIST) has
detected failure with one
component (memory, bus,
interconnects)
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 8
Contact Technical
Support to arrange
replacement.
Table 21: Protocols and Ports
Component
Protocol
(TCP/UDP)
Src Port Dst Port Service Remarks
Source Destination
Access Point UDP CTP
Controller TCP/UDP Any 22 SSH Management
Controller TCP Any 5825 HTTPS
Controller TCP/UDP Any 161 SNMP
Controller TCP/UDP 32768-
65535
Outgoing
connection from
the Controller to
various devices.
Controller Access Point UDP Any 13910
(Subject to
NAPT)
CTP WLAN data and
control tunnel.
Access Point Controller UDP Any 13910 CTP WLAN data and
control tunnel
Access Point Controller UDP 13907 RU
Registration
Table 20: Summit WM Controller WM200/2000 application states (Continued)
Condition
Log
Level
Comment Action