Specifications

Logs and Events
Summit WM Technical Reference Guide, Software Version 5.3150
68 Cannot connect to Radius
Client. Will keep trying until
connection is successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow
authentication to proceed and
therefore blocking any users
from gaining proper access to
network.
If problem persists, contact
Technical Support to
investigate.
69 Cannot connect to EAP. Will
keep trying until connection is
successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow EAP
(WPA) authentication to
proceed and therefore blocking
any users in AAA assigned
WM-ADs.
If problem persists, contact
Technical Support to
investigate.
70 Internal communication failure
- cannot make internal data
connection. Will keep trying
until connection is successful.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to
investigate.
71 Error on socket select. The
socket must have already been
closed.This should not impact
whether an authentication
request succeeds or fails for a
session.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to
investigate.
72 Error accepting new socket.
Will not be able to receive
login information from Apache
server.
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to
investigate.
73 Error trying to send a message
to Radius Client. Captive portal
authentication request will fail.
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to
investigate.
74 Send
SECMGR_MU_AUTHENTICATE
D_NOTIFY message failed for
token%d
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to
investigate.
75 Received failure from Config
Manager for default filter -
configuration is incorrect or
incomplete!
Internal configuration issue
encountered. User filter policy
will be applied as “Default”
rather than more specific
filterID indicated through
radius authentication. User
network access to network may
be different than
administration intended.
If problem persists, contact
Technical Support to
investigate.
Table 36: SECURITY_MANAGER (4) logs and events (Continued)
Log ID Log Message Comment Action