18 Logs and Events
The Summit WM Controller is designed to behave like an appliance. It is either in an operational state,
or it has failed due to a hardware problem or low level packet processing issue. In general, the system
will self recover by rebooting if the system fault is recoverable.
There are two main monitoring processes in the system:
a hardware watchdog
a software watchdog
The software watchdog restarts stalled or failed processes, while the hardware watchdog causes system
reboot should the software watchdog fail. The result of this approach is that little intervention is
required once the system is properly configured and operational.
STARTUP_MANAGER (0)
Table 32: STARTUP_MANAGER (0) logs and events
Log ID Log Message Comment Action
Critical
2 Failed attempting to start
router ports. System reboot
initiated.
Internal communication
problem. Possible
misconfiguration of
system.System will Restart
If problem persists, contact
Technical Support to
investigate.
3 Internal connection to router
ports lost. Restart initiated.
Internal communication
problem. Possible
misconfiguration of system.
System will restart.
If problem persists, contact
Technical Support to
investigate.
4 HSM failed to start. System
reboot initiated.
Internal communication
problem. Possible
misconfiguration of system.
System will restart.
If problem persists, contact
Technical Support to
investigate.
5 HSM is down. System reboot
initiated
Internal communication
problem. Possible
misconfiguration of system.
System will restart.
If problem persists, contact
Technical Support to
investigate.
6 HSM failed to reply to status
notification. System reboot
initiated.
Internal communication
problem. Possible
misconfiguration of system.
System will restart.
If problem persists, contact
Technical Support to
investigate.
7 Failed to connect to Langley.
System reboot initiated.
Internal communication
problem. Possible
misconfiguration of system.
System will restart.
If problem persists, contact
Technical Support to
investigate.