Specifications

Summit WM Technical Reference Guide, Software Version 5.3 119
Termination codes
The RADIUS client (Summit WM Controller or AP) terminates the wireless device user’s session when
one of the following events occur:
user request
idle timeout
session timeout
administrator reset
When a user session is terminated, the RADIUS client sends a RADIUS accounting stop request that
will include one of the following termination codes:
Session-Timeout 27 integer (Accept-response/GUI input)
Class 25 octets (Accept-response)
Login-LAT-Group 36 octets (Accept-response)
Acct-Status-Type 40 integer Stop/Interim-Update
Acct-Terminate-Cause 49 integer Termination code (only in stop packet)
Acct-Authentic 45 integer Radius/Local/Remote
Framed-IP-Address 8 ipaddr Mu_ip_address
Connect-Info 77 string 802.11 a[b][g]
NAS-port-type 61 integer 18/19
Called-Station-ID 30 string BP MAC
Calling-Station-ID 31 string mu_mac_address
Acct-Delay-Time 41 integer
Acct-Session-Time 46 integer
Acct-Input-Packets 47 integer
Acct-Output-Packets 49 integer
Acct-Input-Octets 42 integer
Acct-Output-Octets 43 integer
BP-Serial VSA string Extreme-AP-Serial
BP-Name VSA string Extreme-AP-Name
WM-AD-Name VSA string Extreme-WM-AD-Name
SSID VSA string Extreme-SSID
Table 29: Termination codes
Radius
Value
Radius
Definition
Controller
Value
Controller/SMT Definition Controller Name
1 User Request 9 RF notification that MU has
disconnected from Wireless AP. This
would be the case if there is a Logoff
button for Captive Portal. Normally
this would not apply to 802.1X
connections.
MU_DEREG_REASON_USER
_REQUEST
Table 28: Information elements supported in RADIUS Stop or Interim messages (Continued)
Attribute NO. RAD. Data Type Name