Error conditions:
Summit WM200/2000 Controller back panel
The following figure identifies the main components on the back panel of Summit WM200/2000
Controller.
Figure 8: Summit WM200/2000 Controller back panel
Table 4: LED states and SSD codes during error conditions
Active LED Warning LED Error LED SSD Code Condition
Green Red 1 Failed to identify FDD. Possibly due to removal of
FDD card.
Green Red 2 Failed to initialize NPE card.
Green Red 3 Critical threshold reached (95C for NPE).
The system will reboot.
Green Red 4 Full fan assembly failure (both trays).
The system will reboot.
Green Red 5 Application initialization failure. Startup manager
failed to initialize all the components of the
system.
The system will reboot.
Green Red 6 Lost connectivity with ethernet interface. Possible
failure of NPE card.
The system will reboot.
Green Red 7 MF 1000 card failure. Backup sectors exhausted.
Green Red 8 NP 4000 card initialization failure. Firmware self
test (BIST) has detected failure in one or more
components (memory, bus, interconnects)