Specifications
Summit WM Getting Started Guide, Software Version 5.1 21
NOTE
Although the Active LED will be lit Green during the firmware initialization, this LED state is irrelevant to the SSD
display or the condition. You must ignore the LED state during the firmware initialization.
Application initialization:
Warning conditions:
Green 5 The system is formatting memory.
Green 6 The system is initializing load device.
Note: If the SSD code is stuck at 6 for more than
a minute, it implies that the Network Processor
Card is installed in wrong slot.
Green 9 The system is loading subsystem.
Green b The system is starting the operation system. The
system is active.
Table 2: LED states and SSD codes during application initialization
Active LED Warning LED Error LED SSD Code Condition
Green 0 Application initialization started.
Green 1 Forwarding Engine initialization complete.
Application initialization.
Green A Application initialization complete. System active.
Green H System halted. Administrator requested halting of
system.
Table 3: LED states and SSD codes during warning conditions
Active LED Warning LED Error LED SSD Code Condition
Green Yellow 1 High temperature reached.
Green Yellow 2 Fan unit failure. Rotation counter indicates zero
speed for one of the lateral trays. May be the result
of fan tray removal.
Green Yellow 3 Power supply failure. Failed to detect one of the
power supplies. May be the result of the fan tray
removal of one of the power supplies.
Green Yellow 4 FDD low sector count (40 backup sectors
remaining).
Green Yellow 5 FDD extremely low sector count (20 backup sectors
remaining)
Table 1: LED states and SSD codes during firmware initialization (Continued)
Active LED Warning LED Error LED SSD Codes Condition