Specifications
Summit WM20 Controller Diagnostics
Summit WM20 Technical Reference Guide, Software Version 4.2 61
Summit WM20 Controller LED states and the corresponding system states
Protocols used in the Summit WM20 Controller
Summit WM Software uses several protocols. All the protocols are IP based protocols, and as a result
have corresponding TCP and UDP ports associated with them. You must note the TCP/UDP ports that
are required for the proper functioning of the Summit WM Controller and the Wireless APs.
The following table specifies the protocol ports:
Table 7: Summit WM20 Controller LED states and corresponding system states
System state Status LED Activity LED
Power up (BIOS, POST) Blinking Amber Green
System booting (failed to boot) Off Green
Startup Manager: Task Started Solid Amber Blinking Amber
Startup Manager: Task completes the startup — All
components active
Solid Green Blinking Green upon
traffic activity
A component fails to start or needs restarting
(Startup Manager Task retrying that compoment)
Solid Amber Blinking Green
Possible hardware failure (Fan, temprature) Green Blinking Red
A component fails (no more retries) Solid Red Off
System about to reset by the watchdog Blinking Red Off
System shutdown/halt (Requires manual reboot) Solid Red Solid Red
Table 8: Protocols and Ports
Component
Protocol
(TCP/UDP) Src Port Dst Port Service Remarks
Source Destination
Access Point UDP CTP
Controller TCP/UDP Any 22 SSH Management
Controller TCP Any 5825 HTTPS
Controller TCP/UDP Any 161 SNMP
Controller TCP/UDP 32768-
65535
Outgoing
connection from
the Controller to
various devices.
Controller Access Point UDP Any 13910
(Subject to
NAPT)
CTP WLAN data and
control tunnel.
Access Point Controller UDP Any 13910 CTP WLAN data and
control tunnel
Access Point Controller UDP 13907 RU
Registration
Controller Controller TCP 13907 BM
Availability
Controller Access Point TCP/UDP 69 TFTP