36 Client with MAC%s has failed
authorization on AP <%s>.
Client on specific AP has failed
authentication with controller.
Verify that user in question is
properly configured to access
network.
37 Client session MAC%s has failed
authentication
Client on specific AP has failed
authentication with controller
Verify that user in question is
properly configured to access
network.
Info
65 Socket write failed. The TCP
connection is down. The
authentication request will fail
for the session, however the
secMgr will try to re-connect to
the "downed" component.
Possible outage in user
authentication subsystem. User
will most likely re-attempt to
clear situation.
If problem persists, contact
Technical Support to investigate.
66 Socket read failed with errno%d.
The TCP connection is down.
The authentication request will
fail for the session, however the
secMgr will try to re-connect to
the "downed" component.
Possible outage in user
authentication subsystem. User
will most likely re-attempt to
clear situation.
If problem persists, contact
Technical Support to investigate.
67 Error trying to close all sockets.
However, they will time out on
their own.
No negative impact to system.
However indicates possible issue
with resource de-allocation.
If problem persists, contact
Technical Support to investigate.
68 Cannot connect to Radius
Client. Will keep trying until
connection is successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow
authentication to proceed and
therefore blocking any users
from gaining proper access to
network.
If problem persists, contact
Technical Support to investigate.
69 Cannot connect to EAP. Will
keep trying until connection is
successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow EAP
(WPA) authentication to proceed
and therefore blocking any users
in AAA assigned WM-ADs.
If problem persists, contact
Technical Support to investigate.
70 Internal communication failure -
cannot make internal data
connection. Will keep trying
until connection is successful.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to investigate.
71 Error on socket select. The
socket must have already been
closed.This should not impact
whether an authentication
request succeeds or fails for a
session.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to investigate.
72 Error accepting new socket. Will
not be able to receive login
information from Apache server.
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to investigate.
Table 18: SECURITY_MANAGER (4) logs and events (Continued)