Managing Faults on Virtual Services Platform 7200 Series and 8000 Series Version 5.1.2
Table Of Contents
- Contents
- Chapter 1: Introduction
- Chapter 2: New in this document
- Chapter 3: Fault management fundamentals
- Chapter 4: Key Health Indicators using ACLI
- Chapter 5: Key Health Indicators using EDM
- Chapter 6: Link state change control using ACLI
- Chapter 7: Link state change control using EDM
- Chapter 8: Log and trap fundamentals
- Chapter 9: Log configuration using ACLI
- Configuring a UNIX system log and syslog host
- Configuring secure forwarding
- Installing root certificate for syslog client
- Configuring logging
- Configuring the remote host address for log transfer
- Configuring system logging
- Configuring system message control
- Extending system message control
- Viewing logs
- Configuring ACLI logging
- Chapter 10: Log configuration using EDM
- Chapter 11: SNMP trap configuration using ACLI
- Chapter 12: SNMP trap configuration using EDM
- Glossary
show snmp-server host
Example
Configure the target table entry. Configure an SNMPv3 host.
Switch:1>enable
Switch:1#configure terminal
Switch:1(config)#snmp-server host 198.202.188.207 port 162 v2c ReadView inform timeout
1500 retries 3 mms 484
Switch:1(config)#snmp-server host 198.202.188.207 port 163 v3 authPriv Lab3 inform
timeout 1500 retries 3
Variable definitions
Use the data in the following table to use the snmp-server host command.
Variable Value
inform [timeout <1-2147483647>] [retries
<0-255>] [mms <0-2147483647>]
Sends SNMP notifications as inform (rather than trap). To use all
three options in one command, you must use them in the
following order:
1. timeout <1-2147483647> specifies the timeout value in
seconds with a range of 0–214748364.
2. retries <0-255> specifies the retry count value with a range
of 0–255.
3. mms <0-2147483647> specifies the maximum message
size as an integer with a range of 0–2147483647.
filter WORD<1-32> Specifies the filter profile to use.
noAuthNoPriv|authNoPriv|AuthPriv Specifies the security level.
port <1-65535> Specifies the host server port number.
WORD<1-32> Specifies the security name, which identifies the principal that
generates SNMP messages.
WORD<1-256> Specifies either an IPv4 or IPv6 address.
Configuring an SNMP notify filter table
Configure the notify table to select management targets to receive notifications, as well as the type
of notification to send to each management target.
Before you begin
• For more information about the notify filter table, see RFC3413.
Procedure
1. Enter Global Configuration mode:
SNMP trap configuration using ACLI
January 2017 Managing Faults on Avaya VSP 7200 Series and 8000 Series 60
Comments on this document? infodev@avaya.com