Managing Faults on Avaya Virtual Services Platform 7200 Series and 8000 Series Version 4.2.1
Table Of Contents
- Contents
- Chapter 1: Introduction
- Chapter 2: New in this release
- Chapter 3: Fault management fundamentals
- Chapter 4: Key Health Indicators using ACLI
- Chapter 5: Key Health Indicators using EDM
- Chapter 6: Link state change control using ACLI
- Chapter 7: Link state change control using EDM
- Chapter 8: RMON configuration using ACLI
- Chapter 9: RMON configuration using EDM
- Enabling RMON globally
- Enabling RMON on a port or VLAN
- Enabling RMON1 history
- Disabling RMON1 history
- Viewing RMON1 history statistics
- Creating an RMON1 alarm
- Creating an RMON1 port history alarm
- Viewing RMON1 alarms
- Deleting an RMON1 alarm
- Creating a default RMON1 event
- Creating a nondefault RMON1 event
- Viewing RMON1 events
- Viewing the RMON log
- Deleting an event
- Viewing the protocol directory
- Viewing the data source for protocol distribution statistics
- Viewing protocol distribution statistics
- Viewing the host interfaces enabled for monitoring
- Viewing address mappings
- Viewing the data source for host statistics
- Viewing network host statistics
- Viewing application host statistics
- Chapter 10: Viewing statistics using ACLI
- Chapter 11: Viewing statistics using EDM
- Chapter 12: Log and trap fundamentals
- Chapter 13: Log configuration using ACLI
- Chapter 14: Log configuration using EDM
- Chapter 15: SNMP trap configuration using ACLI
- Chapter 16: SNMP trap configuration using EDM
- Chapter 17: RMON alarm variables
- Glossary
Chapter 9: RMON configuration using EDM
Remote monitoring (RMON) is a management information base (MIB) or a group of management
objects that you use to obtain or configure values using the Simple Network Management Protocol
(SNMP).
Enabling RMON globally
About this task
You must globally enable RMON before you can use an RMON function. If you attempt to enable an
RMON function before the global flag is disabled, EDM informs you that the flag is disabled and
prompts you to enable the flag.
If you want to use nondefault RMON parameter values, you can configure them before you enable
RMON, or as you configure the RMON functions.
Procedure
1. In the navigation tree, expand the following folders: Configuration > Serviceability >
RMON.
2. Click Options.
3. Click the Options tab.
4. Select the Enable check box.
5. In the UtilizationMethod option, select a utilization method.
6. In the TrapOption option, select a trap option.
7. In the MemSize box, type a memory size.
8. Click Apply.
Options field descriptions
Use the data in the following table to use the Options tab.
June 2015 Managing Faults on Avaya VSP 7200 Series and 8000 Series 47
Comments on this document? infodev@avaya.com










