Managing Faults on Avaya Virtual Services Platform 7200 Series and 8000 Series Version 4.2.1

Table Of Contents
Category Subcategory Variable Definition
combining them as they are
received.
icmpInParmProbs.0 The number of ICMP In
parameter problem messages
received.
icmpOutParmProbs.0 The number of ICMP Out
parameter problem messages
received.
MLT rcStatMltEtherAlignmentErrors The number of frames received
on an MLT that are not an integral
number of octets in length, but do
not pass the FCS check.
rcStatMltEtherFCSErrors The number of frames received
on an MLT that are an integral
number of octets in length, but do
not pass the FCS check.
rcStatMltEtherSingleCollFrames The number of successfully
transmitted frames on a particular
MLT where transmission is
inhibited by exactly one collision.
rcStatMltEtherMultipleCollFrames The number of successfully
transmitted frames on a particular
MLT where transmission is
inhibited by more than one
collision.
rcStatMltEtherSQETestError A count of times that the SQE
TEST ERROR message is
generated by the PLS sublayer
for a particular MLT.
rcStatMltEtherDeferredTransmiss A count of frames where the first
transmission attempt on a
particular MLT is delayed
because the medium is busy. The
count represented by an instance
of this object.
rcStatMltEtherLateCollisions The number of times that a late
collision is detected on a
particular MLT later than 512 bit-
times into the transmission of a
packet; 512-bit-times corresponds
to 51.2-microseconds on a 10
Mb/s system.
rcStatMltEtherExcessiveCollis The number of times that
excessive collisions are detected
Table continues…
RMON alarm variables
116 Managing Faults on Avaya VSP 7200 Series and 8000 Series June 2015
Comments on this document? infodev@avaya.com