Installation Instructions
Table Of Contents
- Contents
- Chapter 1: Introduction
- Chapter 2: New in this document
- Chapter 3: Optical routing design
- Chapter 4: Safety and equipment care information
- Chapter 5: SFP
- SFP transceivers
- SFP specifications
- SFP labels
- General SFP specifications
- Supported SFP transceivers
- Autonegotiation
- 1000BASE-SX (LC) SFP specifications
- 1000BASE-SX (MT-RJ) SFP specifications
- 1000BASE-LX SFP specifications
- 1000BASE-XD CWDM SFP specifications
- 1000BASE-ZX CWDM (LC) SFP specifications
- 1000BASE-T SFP specifications
- 1000BASE-SX DDI SFP specifications
- 1000BASE-LX DDI SFP specifications
- 1000BASE-XD DDI 1310 nm SFP specifications
- 1000BASE-XD DDI 1550 nm SFP specifications
- 1000BASE-ZX DDI 1550 nm SFP specifications
- 1000BASE-XD DDI CWDM (40 km) SFP specifications
- 1000BASE-ZX DDI CWDM 70 km SFP specifications
- 1000BASE-BX bidirectional SFP transceivers
- 1000BASE-EX DDI SFP specifications
- 100BASE-FX SFP specifications
- Chapter 6: SFP+
- SFP+ transceivers
- SFP+ specifications
- SFP+ labels
- General SFP+ specifications
- Supported SFP+ transceivers
- 10GBASE-T SFP+ transceiver
- 10GBASE-LR/LW SFP+ specifications
- 10GBASE-LR/LW SFP+ high temperature (-5 °C to +85 °C) specifications
- 10GBASE-ER/EW SFP+ specifications
- 10GBASE-SR/SW SFP+ specifications
- 10GBASE-SR/SW SFP+ high temperature (0 °C to +85 °C) specifications
- 10GBASE-ZR/ZW SFP+ specifications
- 10GBASE-CX specifications
- 10GBASE CWDM DDI SFP+ (40 km) specifications
- 10GBASE-LRM SFP+ specifications
- 10GBASE CWDM DDI SFP+ (70 km) specifications
- 10GBASE-BX SFP+ specifications
- SFP+ cable assembly specifications
- Chapter 7: QSFP+
- Chapter 8: Translations of safety messages
- Class A electromagnetic interference warning statement
- Electrostatic discharge warning statement
- Laser eye safety danger statement
- Laser eye safety connector inspection danger statement
- Connector cleaning safety danger statement
- Optical fiber damage warning statement
- Optical fiber connector damage warning statement
- SFP damage warning statement
- Glossary
10GBASE-CX specifications
The 10GBASE-CX is a 2-pair twinaxial copper cable that plugs into the SFP+ socket and connects
two 10-gigabit ports. The reach for this cable is up to 15 m with a bit error rate (BER) better than
10
-12
.
The 10GBASE-CX is a lower cost alternative to the optical SFP+ devices.
For more information about the 10GBASE-CX, including test and measurement information and
more specifications, see the IEEE 802.3–2012 standard. The following table identifies the part
numbers for specific cable lengths.
Table 30: 10GBASE-CX cables
Cable length Part number
3 meter AA1403019-E6
5 meter AA1403020-E6
7 meter AA1403022-E6
10 meter AA1403018-E6
15 meter AA1403021-E6
10GBASE CWDM DDI SFP+ (40 km) specifications
The following table lists the part numbers of the 10GBASE CWDM DDI SFP+ (40 km) with
corresponding wavelengths.
Table 31: Part number and center wavelength assignment
Part number Center
wavelength
assignment
Reach Insertion loss
Tx to Rx
AA1403153-E6 1471 nm up to 40 km 5 dB
AA1403154-E6 1491 nm up to 40 km 5 dB
AA1403155-E6 1511 nm up to 40 km 5 dB
AA1403156-E6 1531 nm up to 40 km 5 dB
AA1403157-E6 1551 nm up to 40 km 5 dB
AA1403158-E6 1571 nm up to 40 km 5 dB
AA1403159-E6 1591 nm up to 40 km 5 dB
AA1403160-E6 1611 nm up to 40 km 5 dB
The following table lists the transmitter and receiver specifications for the 10GBASE CWDM DDI
SFP+ (40 km).
SFP+ specifications
December 2016 Installing Transceivers and Optical Components on Avaya VSP Operating System
Software 59