Admin Guide

Table Of Contents
Variable Value
The first <1–99> variable specifies the first
notification, the second <1–99> specifies the second
notification, and the third <1–99> variable specifies
the third interval.
By default, the first interval is 1 day, the second
interval is 7 days, and the third interval is 30 days.
System access configuration using EDM
The section provides procedures you can use to manage system access by using Enterprise Device
Manager (EDM). Procedures include configurations for usernames, passwords, and access policies.
Enabling access levels
About this task
Enable access levels to control the configuration actions of various users.
Important:
Only the RWA user can disable an access level on the switch. You cannot disable the RWA
access level on the switch.
The system preserves these configurations across restarts.
Procedure
1. In the navigation tree, open the following folders: Configuration > Security > Control Path.
2. Click General.
3. Click the CLI tab.
4. Select the enable check box for the required access level.
5. Click Apply.
CLI field descriptions
Use the data in the following table to use the CLI tab.
Name
Description
RWAUserName Specifies the user name for the read-write-all CLI account.
RWAPassword Specifies the password for the read-write-all CLI account.
RWEnable Activates the read-write access. The default is enabled.
Table continues…
System access
October 2015 Administering Avaya VSP 7200 Series and 8000 Series 194
Comments on this document? infodev@avaya.com