Troubleshooting Guide

Table Of Contents
Variable Value
the logs. The last three characters denote the sequence
number of the log file. Multiple sequence numbers are
generated for the same chassis and same slot, if the
maximum log file size is reached.
loadconfigtime Configures the timeout for loading the configuration file in
seconds. The values are 0 to 300 seconds.
multicast Configures the system multicast scaling parameter. The
multicast scaling values are 0 to 2147483647.
sio Configures CPU serial port devices.
logfile <64-500> <500-16384> <10-90> Configures the logfile parameters
<64-500> specifies the minimum free memory space on
the external storage device from 64–500 KB. Virtual
Services Platform 4000 does not support this parameter.
<500-16384> specifies the maximum size of the log file
from 500–16384 KB.
<10-90> specifies the maximum percentage, from 10–
90%, of space on the external storage device the logfile
can use. Virtual Services Platform 4000 does not support
this parameter.
Configuring system message control
Before you begin
You must log on to the Global Configuration mode in ACLI.
About this task
Configure system message control to suppress duplicate error messages on the console, and to
determine the action to take if they occur.
Procedure
1. Configure system message control action:
sys msg-control action <both|send-trap|suppress-msg>
2. Configure the maximum number of messages:
sys msg-control max-msg-num <2-500>
3. Configure the interval:
sys msg-control control-interval <1-30>
4. Enable message control:
sys msg-control
Log configuration using ACLI
January 2017 Troubleshooting 56
Comments on this document? infodev@avaya.com