Troubleshooting Guide

Table Of Contents
Variable Value
platform supports channelization for 40 Gbps ports
and the port is channelized, you must also specify
the sub-port in the format slot/port/sub-port.
Displays Fabric Attach statistics on ports.
Use the data in the following table to use the clear fa statistics command.
Variable Value
summary Clears global level fabric attach statistics
{slot/port[/sub-port][-slot/port[/sub-port]][,...]} Identifies the slot and port in one of the following
formats: a single slot and port (slot/port), a range of
slots and ports (slot/port-slot/port), or a series of
slots and ports (slot/port,slot/port,slot/port). If your
platform supports channelization for 40 Gbps ports
and the port is channelized, you must also specify
the sub-port in the format slot/port/sub-port.
Clears Fabric Attach statistics on ports.
Related links
Viewing Fabric Attach statistics on page 317
Viewing Fabric Attach I-SID-to-VLAN assignments
Use this procedure to display the I-SID-to-VLAN assignments advertised by an FA Client or an FA
Proxy, to be supported on the FA Server. These assignments can be accepted or rejected by the FA
Server. An assignment that is successfully accepted by the FA Server results in the creation of a
Switched UNI I-SID on the interface.
Before you begin
Verify that IS-IS and SPBM are properly configured on the FA Server switch.
Verify SPBM configuration using the command show running-config module spbm.
Verify IS-IS configuration using one of the following commands:
-
show isis
-
show isis interface
-
show isis adjacency
-
show isis lsdb
Procedure
1. Enter Privileged EXEC mode:
enable
2. Display FA I-SID-to-VLAN assignments:
show fa assignment
3. Display FA I-SID-to-VLAN assignments on specific ports:
Troubleshooting Fabric Attach
January 2017 Troubleshooting 320
Comments on this document? infodev@avaya.com