Troubleshooting Guide

Table Of Contents
Field Description
DEST-MAC Specifies the virtual BMAC address or system ID, in
MAC format, of the destination node.
BVLAN Specifies the BVLAN on which the destination node
is discovered for the I-SID.
DEST-SYSNAME Specifies the destination system name.
Viewing I-SID maximum MAC-limit
Perform this procedure to view the maximum MAC learning limit information for an I-SID.
Important:
The command show i-sid limit-fdb-learning is supported only on the Avaya Virtual
Services Platform 4000 Series.
About this task
The total MAC learning limit per switch is 32000. MAC learning on I-SID stops when the maximum
limit is reached.
Procedure
View the maximum MAC learning limit configured for an I-SID:
show i-sid limit-fdb-learning <1-16777215>
Example
View maximum MAC learning limit for all I-SIDs.
Switch:1#show i-sid limit-fdb-learning
=========================================
Isid MAC-Limit Info
=========================================
ISID MAC-LIMIT MAXMAC
ID STATUS COUNT
-----------------------------------------
10 disabled 32000
11 disabled 32000
12 disabled 32000
15 disabled 32000
101 disabled 32000
All 5 out of 5 Total Num of i-sid Info displayed
View maximum MAC learning limit for a specific I-SID.
Switch:1#show i-sid limit-fdb-learning 10
=========================================
Isid MAC-Limit Info
=========================================
ISID MAC-LIMIT MAXMAC
Transparent Port UNI feature troubleshooting using ACLI