Configuring autogenerated CFM on C-VLANs
This procedure applies only to VSP 4000 Series.
Use this procedure to configure the autogenerated CFM MEP and MIP level for every C-VLAN on
the chassis.
To configure autogenerated CFM on SPBM B-VLANs, see Configuring autogenerated CFM on
SPBM B-VLANs on page 184.
Important:
CFM supports one MEP or MIP on each C-VLAN. Only autogenerated CFM provides support
for configuring MEP and MIPs on C-VLANs. You cannot explicitly configure C-VLANs.
About this task
When you enable this feature, you create a global MD (named cmac) for all the customer MAC (C-
MAC) MEPs. This MD has a default maintenance level of 4, which you can change with the level
attribute. The autogenerated CFM commands also create an MA for each C-VLAN, a MEP for each
C-VLAN, and associate the MEP with the corresponding C-VLAN and a MIP with the C-VLAN.
All the MEPs that the device creates use the MEP ID configured under the global context, which has
a default value of 1. The device automatically associates the MEPs with the C-VLANs configured.
The MIP level maps to the global level. The device automatically associates the MIP level with the
C-VLANs configured when you enable the feature.
The feature is disabled by default.
Procedure
1. From the navigation tree, expand the following folders: Configuration > Edit > Diagnostics.
2. Click CFM.
3. Click the Global tab.
4. Select enable next to CmacAdminState.
5. In the fields provided, specify a maintenance level and a MEP ID.
6. Click Apply.
CFM Global field descriptions
Use the data in the following table to configure the global MEP and MIP parameters.