Troubleshooting Guide

Table Of Contents
Before you begin
On the source and destination nodes, you must configure an autogenerated or an explicit CFM
MD, MA, and MEP.
Enable the MEP.
Assign a nodal MEP to the B-VLAN.
Procedure
1. Log on to the switch to enter User EXEC mode.
2. Trigger a Layer 2 tracemroute on the VLAN:
l2 tracemroute source <A.B.C.D> group <A.B.C.D> vlan
<1-4059>[priority <0–7>] [ttl—value <1–255>]
Note:
For the preceding command, if you do not specify a VLAN, l2 tracemroute uses the
global default VRF.
Wait for the l2 tracemroute to complete or press any key to abort.
3. Trigger a Layer 2 tracemroute on the VRF:
l2 tracemroute source <A.B.C.D> group <A.B.C.D> vrf WORD<1–16>
[priority <0–7>] [ttl—value <1–255>]
Note:
For the preceding command, if you do not specify a VRF, l2 tracemroute uses the
global default VRF.
Wait for the l2 tracemroute to complete or press any key to abort.
Example
The following is a sample output for a Layer 2 tracemroute on a VLAN:
Switch:1>enable
Switch:1#configure terminal
Switch:1(config)#l2 tracemroute source 192.0.2.81 233.252.0.1 vlan 201
Please wait for l2 tracemroute to complete or press any key to abort.
Source 192.0.2.81
Group: 233.252.0.1
VLAN:201
BMAC: 03:00:03:f4:24:01
B-VLAN: 10
I-SID: 16000001
===============================================================
1 PETER4 00:03:00:00:00:00 -> LEE1 00:14:0d:bf:a3:df
2 LEE1 00:14:0d:bf:a3:df -> LEE2 00:15:e8:b8:a3:df
Operations and Management
January 2017 Troubleshooting 176