Troubleshooting Guide

Table Of Contents
VSP-4850GTS> show cfm maintenance-endpoint
================================================================================
Maintenance Endpoint Config
================================================================================
DOMAIN ASSOCIATION MEP ADMIN
NAME NAME ID
--------------------------------------------------------------------------------
md1 ma1 1 enable
Total number of MEP entries: 1.
================================================================================
Maintenance Endpoint Service
================================================================================
DOMAIN_NAME ASSN_NAME MEP_ID TYPE SERVICE_DESCRIPTION
--------------------------------------------------------------------------------
md1 ma1 1 unused
Total number of MEP entries: 1.
Variable definitions
Use the data in the following table to use the cfm maintenance-endpoint command.
Variable Value
WORD<0–22> The first parameter, specifies the MD name.
WORD<0–22> The second parameter, specifies the MA name.
<1–8191> Specifies the MEP ID.
state {enable | disable} Enables or disables the MEP when creating the MEP. The
default is disabled.
enable Enables an existing MEP. Use this parameter with the no option
to disable an existing MEP.
Assigning a MEP/MIP level to an SPBM B-VLAN
Use this procedure to assign a nodal MEP to an SPBM B-VLAN. The Nodal MEP provides
traceability and troubleshooting at the system level for a given B-VLAN. The Nodal B-VLAN MEPs
created on the CP and function as if they are connected to the virtual interface of the given B-VLAN.
Because of this they are supported for both port and MLT based B-VLANs.
Nodal MPs provide both MEP and MIP functionality for SPBM deployments. Nodal MPs are
associated with a B-VLAN and are VLAN encapsulated packets. Each node (chassis) has a given
MAC address and communicates with other nodes. The SPBM instance MAC address is used as
the MAC address of the Nodal MP.
Before you begin
You must configure a CFM MD, MA, and MEP.
Procedure
1. Add nodal MEPs to the B-VLAN:
vlan nodal-mep <1-4059> WORD<0–22> WORD<0–22> <1–8191>
CFM configuration using ACLI
January 2017 Troubleshooting 163
Comments on this document? infodev@avaya.com