level attribute. The autogenerated CFM commands also create an MA for each C-VLAN, a MEP for
each C-VLAN, associate the MEP with the corresponding C-VLAN, and a MIP with the C-VLAN.
All the MEPs that the device creates use the MEP ID configured under the global context, which has
a default value of 1. The device automatically associates the MEPs with the C-VLANs configured.
The MIP level maps to the global level. The device automatically associates the MIP level with the
C-VLANs configured when you enable the feature.
The feature is disabled by default.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. Configure the maintenance level for every CFM C-MAC MEP and MP level on all the C-
VLANs:
cfm cmac level <0–7>
Only configure global CFM at one MD level for each chassis for each VLAN type.
3. Assign a global CFM MEP ID for all CFM C-MAC MEPs:
cfm cmac mepid <1-8191>
4. Enable the autogenerated CFM for C-VLANs:
cfm cmac enable
5. (Optional) Configure the maintenance level for every CFM C-MAC MEPs and MP level on
all the C-VLANs to the default:
default cfm cmac level
6. (Optional) Assign a global CFM MEP ID for all CFM C-MAC MEPs to the default:
default cfm cmac mepid
7. (Optional) Disable the global CFM MEPs and MIPs:
no cfm cmac enable
8. Display the global CFM MEP configuration:
show cfm cmac
Example
Configure autogenerated CFM MEPs and MIP level:
VSP-4850GTS>enable
VSP-4850GTS#configure terminal
VSP-4850GTS(config)#cfm cmac level 0
VSP-4850GTS(config)#cfm cmac mepid 4
VSP-4850GTS(config)#cfm cmac enable
VSP-4850GTS(config)#show cfm cmac
LEVEL ADMIN MEPID MAC