Installation Instructions

Table Of Contents
Avaya Virtual Services Platform 4000 Switch 4850GTS and
4850GTS-PWR+
The following table describes the regulatory AC power specifications for the Avaya Virtual
Services Platform 4000 4850GTS and 4850GTS-PWR+ switches. It should be noted that
regulatory power specifications are based on the maximum rated capacity of the power
supplies and are not based on typical power consumption which is typically lower.
Table 8: AC power specifications
4850GTS 4850GTS-PWR+
Input Current: 5A/2.5A 12A/6A
Input Voltage (rms): 100 to 240VAC at 50 to 60 Hz 100 to 240VAC at 50 to 60 Hz
Power Consumption: 94.6W maximum 248W maximum
Thermal Rating: 323 BTU/Hr maximum 508 BTU/Hr maximum
Inrush Current: 40A maximum 70A maximum
Turn on Condition: 1 second maximum after
application of AC power
1 second maximum after
application of AC power
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and
monotonic under all defined input and output conditions.
Efficiency: 70 percent minimum 70 percent minimum
Avaya Virtual Services Platform power supply power
specification
VSP
4850GTS-PWR+ supports two external field replaceable power supplies. You can install
a secondary power supply to provide redundancy, load sharing, and add Power over Ethernet
Plus (PoE+) power budget on PWR+ models.
VSP 4850GTS-PWR+ supports dual 54V 1000W Power over Ethernet Plus (PoE+) AC power
supplies.
Avaya Virtual Services Platform power supply power specification
Installation May 2013 35