Installation Instructions
Table Of Contents
- Contents
- Chapter 1: Introduction
- Chapter 2: New in this document
- Chapter 3: Optical routing design
- Chapter 4: Safety and equipment care information
- Chapter 5: SFP
- SFP transceivers
- SFP specifications
- SFP labels
- General SFP specifications
- Supported SFP transceivers
- Autonegotiation
- 1000BASE-SX (LC) SFP specifications
- 1000BASE-SX (MT-RJ) SFP specifications
- 1000BASE-LX SFP specifications
- 1000BASE-XD CWDM SFP specifications
- 1000BASE-ZX CWDM (LC) SFP specifications
- 1000BASE-T SFP specifications
- 1000BASE-SX DDI SFP specifications
- 1000BASE-LX DDI SFP specifications
- 1000BASE-XD DDI 1310 nm SFP specifications
- 1000BASE-XD DDI 1550 nm SFP specifications
- 1000BASE-ZX DDI 1550 nm SFP specifications
- 1000BASE-XD DDI CWDM (40 km) SFP specifications
- 1000BASE-ZX DDI CWDM 70 km SFP specifications
- 1000BASE-BX bidirectional SFP transceivers
- 1000BASE-EX DDI SFP specifications
- 100BASE-FX SFP specifications
- Chapter 6: SFP+
- SFP+ transceivers
- SFP+ specifications
- SFP+ labels
- General SFP+ specifications
- Supported SFP+ transceivers
- 10GBASE-T SFP+ transceiver
- 10GBASE-LR/LW SFP+ specifications
- 10GBASE-LR/LW SFP+ high temperature (-5 °C to +85 °C) specifications
- 10GBASE-ER/EW SFP+ specifications
- 10GBASE-SR/SW SFP+ specifications
- 10GBASE-SR/SW SFP+ high temperature (0 °C to +85 °C) specifications
- 10GBASE-ZR/ZW SFP+ specifications
- 10GBASE-CX specifications
- 10GBASE CWDM DDI SFP+ (40 km) specifications
- 10GBASE-LRM SFP+ specifications
- 10GBASE CWDM DDI SFP+ (70 km) specifications
- 10GBASE-BX SFP+ specifications
- SFP+ cable assembly specifications
- Chapter 7: QSFP+
- Chapter 8: Translations of safety messages
- Class A electromagnetic interference warning statement
- Electrostatic discharge warning statement
- Laser eye safety danger statement
- Laser eye safety connector inspection danger statement
- Connector cleaning safety danger statement
- Optical fiber damage warning statement
- Optical fiber connector damage warning statement
- SFP damage warning statement
- Glossary
For more information about the 10GBASE-SR/SW SFP+ transceiver (0 °C to +85 °C), including test
and measurement information, see the IEEE 802.3ae standard.
Warning:
Risk of equipment damage
To prevent damage to the optical receiver, ensure that at least 1 dB of attenuation exists
between the transmit and receive ports.
Table 28: IEEE 802.3ae 10GBase–SR/SW SFP+ (0 °C to +85 °C) transceiver specifications
Parameter Specifications
Data rate 10 Gbps
Line rate (64B/66B code) 10.3125 gigabits per second (Gbps) ± 100 parts per million
(ppm)
Center wavelength range 840 to 860 nanometers (nm), nominal 850 nm
Distance Using 62.5 µm MMF optic cable:
• 160 MHz-km fiber: 2 to 26 m
• 200 MHz-km fiber: 2 to 33 m
Using 50 µm MMF optic cable:
• 400 MHz-km fiber: 2 to 66 m
• 500 MHz-km fiber: 2 to 82 m
• 2000 MHz-km fiber (OM3): 2 to 300 m
• 4700 MHz-km fiber (OM4): 2 to 400 m
Link optical power budget 7.3 dB
Maximum transmitter and dispersion penalty 3.9 dB at 300 m
Operating case temperature range 0 °C to +85 °C
Transmitter characteristics
Root-mean-square spectral width 0.05 to 0.40 nm
Launch power –7.3 to –1.0 dBm
Minimum extinction ratio 3.0 dB
Maximum optical return loss tolerance –12 dB
Receiver characteristics
Average receive power for BER 10
-12
–9.9 to –1.0 dBm
Receiver damage threshold 0dBm
Maximum receiver sensitivity in OMA –11.1 dBm
Maximum receiver reflectance –12 dB
Stressed receiver sensitivity in OMA –7.5 dBm
SFP+ specifications