Installation Instructions
Table Of Contents
- Notices
- Safety messages
- Before you begin
- Installing the Virtual Services Platform 4000 on a table or shelf
- Installing the Virtual Services Platform 4000 in an equipment rack
- Installing SFP transceivers
- Removing SFP transceivers
- AC power supply specifications
- VSP 4000 power supply power specification
- Installing the Virtual Services Platform 4000 power supply
- Connecting to AC power
Table 1: AC power specifications for 4850GTS series
Specifications 4850GTS 4850GTS-PWR+
Input Current 5A/2.5 A 12A/6A
Input Voltage (rms) 100 to 240 VAC at 50 to 60 Hz 100 to 240 VAC at 50 to 60 Hz
Power Consumption 94.6 W maximum 248 W maximum
Thermal Rating 323 BTU/hr maximum 508 BTU/hr maximum
Inrush Current 40 A maximum 70 A maximum
Turn on Condition 1 second maximum after
application of AC power
1 second maximum after
application of AC power
Important:
12-volt output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency 70 percent minimum 70 percent minimum
VSP 4000 power supply power specification
The VSP 4000 supports two external field-replaceable power supplies. One power supply ships with
the chassis. You can install a secondary power supply to provide redundancy and load sharing, and
to add Power over Ethernet Plus (PoE+) power budget on PWR+ models.
300 W AC power supply
The VSP 4850GTS supports 300 W AC power supplies.
Figure 1: 300 W AC power supply
November 2017 Installation Job Aid for VSP 4850GTS 8