Installation Instructions
Table Of Contents
- Contents
- Chapter 1: Preface
- Chapter 2: New in this document
- Chapter 3: Hardware models
- Chapter 4: Preinstallation checklist
- Chapter 5: Installing the VSP 4450GTX-HT-PWR+
- Installation checklist
- Installation fundamentals
- Electrostatic discharge
- Technical specifications
- Environmental requirements
- Airflow direction
- Package contents
- Installing the Virtual Services Platform 4000 on a table or shelf
- Installing the Virtual Services Platform 4000 in an equipment rack
- Cable requirements for the Virtual Services Platform 4000
- Installation and removal of Small Form Factor Pluggable (SFP) transceivers
- RJ45 connector pin assignments
- Console port pin assignments
- Installing the Virtual Services Platform 4000 power supply
- Connect AC power
- LED state definitions
- Viewing hardware information
- Chapter 6: Translations of safety messages
Environmental requirement Virtual Services Platform 4000 models
Miscellaneous Operating
Considerations
• No heat sources such as hot air vents or direct sunlight near the
switch.
• No sources of severe electromagnetic interference near the switch.
• No excessive dust in the environment.
• An adequate power source is within 6 feet (1.83 meters) of the switch.
One 15-amp circuit is required for each power supply.
• At least 2 inches (5.08 centimeters) of clearance on each side of the
switch unit for ventilation.
• Adequate clearance at the front and rear of the switch for access to
cables.
Warning:
To avoid bodily injury from hazardous electrical shock and current, never remove the top of the
device. No user-serviceable components are inside. For a translation of this statement, see
Translations of safety messages on page 39.
Airflow direction
The airflow direction in the VSP 4450GTX-HT-PWR+ for the top half of the switch, where the
components exist, is from left to right (as viewed from the front). Cool air enters the chassis through
an air inlet at the left of the chassis, which cools the device. Warm air exits through the exhaust at
the right.
The airflow direction for the bottom half of the VSP 4450GTX-HT-PWR+, where the power supplies
exist, is from front to back. The chassis draws in cool air from the front of the chassis, and hot air
exits at the rear.
Package contents
The following describes the components that are provided with each switch. If any components are
missing, contact the switch vendor.
1. VSP 4450GTX-HT-PWR+ switch with one power supply installed
2. Rack-mounting hardware that includes:
• Rack-mount brackets
• Screws to attach brackets to the switch
• Screws to attach the switch to the equipment rack
Installing the VSP 4450GTX-HT-PWR+
August 2018 Installing the Virtual Services Platform 4450GTX-HT-PWR+ 20










