Installation Instructions
Table Of Contents
- Starting the ONA
- Connecting the ONA to the network
- Connecting your device to the ONA
- Setting the ONA to factory defaults
- ONA Operational Modes
- Modifying Manual Configuration parameters
- System Status LED
- Power LED
- 10/100/1000 RJ-45 Port LEDs
- Restarting the ONA
- Running diagnostics on the ONA
- Upgrading a standalone ONA using the Manual Configuration menu
- Upgrading a deployed ONA
Label Color and Status Description
Blue (blinking) ONA is starting
Off Not operational
10/100/1000 RJ-45 Port LEDs
The RJ-45 ports on both the Network side and Device side of the ONA have two bi-colored (amber/
green) LEDs. The one on the left side indicates the port speed and the one on the right side shows
the level of link activity.
Label Color and Status Description
Speed Amber (steady) 100 Mbps
Amber (blinking) N/A
Green (steady) 1000 Mbps
Green (blinking) N/A
Off 10 Mbps
Link/Activity Amber (steady) N/A
Amber (blinking) N/A
Green (steady) Blink rate indicates level of link
activity
Green (blinking) Blink rate indicates level of link
activity
Green (blinking slow) Port disabled
Off No Link
Restarting the ONA
Restart the ONA by disconnecting and then reconnecting power as described below:
• If the ONA is connected to a PoE capable network switch, disconnect the Ethernet cable
connected to the RJ-45 port with the cloud symbol. Wait at least 45 seconds and then
reconnect it.
• If the ONA is connected to an external power adapter, disconnect it for at least 45 seconds and
then reconnect it.
Running diagnostics on the ONA
Use the diagnostics to verify that the ONA is operating properly.
To enter Diagnostics, use following procedure:
December 2017 Open Networking Adapter 1101GT Installation Job Aid 17