Installation Instructions

Table 5: Physical specifications
Specifications 4450GSX-PWR+ 4450GSX-DC
Height 4.4 cm. – 1U 4.4 cm. – 1U
Width 44 cm. 44 cm.
Depth 43.6 cm. 43.68 cm.
Weight 17.2lbs (7.80 kg) with 1 PSU
installed.
A PSU weighs 3.1 lbs (1.40 kg)
17.2lbs (7.80 kg) with 1 PSU
installed.
A PSU weighs 3.1 lbs (1.40 kg)
MTBF rating chassis – 293,000 hours
1000 W AC power supply –
860,175 hours
chassis – 308,000 hours
300 W DC power supply – 782,296
hours
Environmental requirements
The following table provides the environmental requirements for the individual switches in this
series. Ensure that the area where you install the switch and where it operates meets these
requirements.
Table 6: Virtual Services Platform 4000 environmental requirements
Environmental requirement Virtual Services Platform 4000 models
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating and Storage Humidity 0 to 95 percent noncondensing
Maximum Operating Altitude 3,048m (10 000 feet) above sea level
Altitude 0 to 3,048m (0 to 10,000ft) above sea level
Storage Altitude 0 to 12,192m (0 to 40,000ft) above sea level
Acoustic Noise Less than or equal to 45 db at 35°C and less than or equal to 57 db at
50°C. The temperature is allowed to have ±3.5°C deviation around the
threshold of 35C, (measurement methods based on ISO 7779).
Miscellaneous Operating
Considerations
No heat sources such as hot air vents or direct sunlight near the
switch.
No sources of severe electromagnetic interference near the switch.
No excessive dust in the environment.
An adequate power source is within 6 feet (1.83 meters) of the switch.
One 15-amp circuit is required for each power supply.
At least 2 inches (5.08 centimeters) of clearance on each side of the
switch unit for ventilation.
Table continues…
Installing the VSP 4450GSX-PWR+ series
August 2018 Installing the Virtual Services Platform 4450GSX-PWR+ 20