Installation Instructions

Table Of Contents
Connector Pin Number Signal
6 Receive data (RXD) — mandatory
7 Data set ready (DSR) — optional
8 Clear to send (CTS) — optional, can swap or link with
pin 1
Power specifications for the Avaya Virtual Services Platform
4000
This section describes power specifications for the Avaya VSP 4000 switches.
Avaya Virtual Services Platform 4000 Switch 4850GTS and
4850GTS-PWR+
The following table describes the regulatory AC power specifications for the Avaya Virtual
Services Platform 4000 4850GTS and 4850GTS-PWR+ switches. The regulatory power
specifications are based on the maximum rated capacity of the power supplies and are not
based on typical power consumption which is lower.
Table 10: AC power specifications
4850GTS 4850GTS-PWR+
Input Current: 5A/2.5A 12A/6A
Input Voltage (rms): 100 to 240VAC at 50 to 60 Hz 100 to 240VAC at 50 to 60 Hz
Power Consumption: 94.6W maximum 248W maximum
Thermal Rating: 323 BTU/Hr maximum 508 BTU/Hr maximum
Inrush Current: 40A maximum 70A maximum
Turn on Condition: 1 second maximum after
application of AC power
1 second maximum after
application of AC power
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and
monotonic under all defined input and output conditions.
Efficiency: 70 percent minimum 70 percent minimum
Power specifications for the Avaya Virtual Services Platform 4000
Installation February 2014 37