Design Reference
Table Of Contents
- Contents
- Chapter 1: Introduction
- Chapter 2: New in Release 4.0.50
- Chapter 3: New in Release 4.0.40
- Chapter 4: New in Release 4.0
- Chapter 5: Network design fundamentals
- Chapter 6: Hardware fundamentals and guidelines
- Chapter 7: Optical routing design
- Chapter 8: Platform redundancy
- Chapter 9: Link redundancy
- Chapter 10: Layer 2 loop prevention
- Chapter 11: Spanning tree
- Chapter 12: Layer 3 network design
- Chapter 13: SPBM design guidelines
- Chapter 14: IP multicast network design
- Multicast and VRF-Lite
- Multicast and MultiLink Trunking considerations
- Multicast scalability design rules
- IP multicast address range restrictions
- Multicast MAC address mapping considerations
- Dynamic multicast configuration changes
- IGMPv3 backward compatibility
- IGMP Layer 2 Querier
- TTL in IP multicast packets
- Multicast MAC filtering
- Guidelines for multicast access policies
- Multicast for multimedia
- Chapter 15: System and network stability and security
- Chapter 16: QoS design guidelines
- Chapter 17: Layer 1, 2, and 3 design examples
- Chapter 18: Software scaling capabilities
- Chapter 19: Supported standards, RFCs, and MIBs
- Glossary
Chapter 3: New in Release 4.0.40
The following sections detail what is new in Network Design Reference for Avaya Virtual Services
Platform 4000 Series, NN46251–200 for Release 4.0.40.
Related Links
Features on page 13
Other changes on page 14
Features
See the following sections for information about feature-related changes.
VSP 4450GTX-HT-PWR+
Release 4.0.40 of the Avaya Virtual Services Platform 4000 Series introduces a new hardware
chassis, the VSP 4450GTX-HT-PWR+. This model is designed to withstand an environment with
high-temperature operating conditions. Optimal operating temperature inside the device is
maintained by five 12–volt fans that are speed controlled based on the temperature inside the
device.
The VSP 4450GTX-HT-PWR+ has the following features:
• 48 10/100/1000 BASE TX RJ-45 ports with 802.3at PoE+
Table 1: Maximum PoE+ wattage based on operating temperature
0°C to 50°C
50°C to 70°C
1 PSU 860 W 400 W
2 PSUs 1660 W 832 W
• Two shared small form-factor pluggable (SFP) ports and two 1–gigabit/10–gigabit SFP+ ports
• One field-replaceable 1000 W AC power supply unit (PSU)
It also supports the addition of a second field-replaceable AC PSU for redundancy or additional
PoE.
Note:
The 1000 W AC PSU uses the IEC 60320 C16 AC power cord connector.
For more information about installing the VSP 4450GTX-HT-PWR+, see Installing the Avaya Virtual
Services Platform 4000 Series 4450GTX-HT-PWR+, NN46251–304.
December 2014 Network Design Reference for Avaya VSP 4000 Series 13