Specifications
4
WWW.EXTREMENETWORKS.COM
Environmental Compliance
• EU RoHS – 2011/65/EU
• EU WEEE – 2012/19/EU
• China RoHS – SJ/T 11363-2006
• Taiwan RoHS CNS 15663(2013.7)
Operating Conditions
• Temp: 0° C to 50° C (32° F to 122° F) – all models
• Humidity: 10% to 95% relative humidity, non-condensing
• Altitude: 0 to 3,000 meters (9,842 feet) – all models Shock
(half sine): 30 m/s2 (3 G), 11 ms, 6 shocks
• Random vibration: 3 to 500 Hz at 1.5 G rms
Packaging and Storing Specifications
• Temp: -40° C to 70° C (-40° F to 158° F)
• Humidity: 10% to 95% relative humidity, non-condensing
• Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks
• Packaged Vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500
Hz at 0.2 G
• Packaged Random Vibration: 5 to 20 Hz at 1.0 ASD w/-3 dB/
oct. from 20 to 200 Hz
• Packaged Drop Height 14 drops minimum on sides and corners
at 42 inches (<15 kg box)
Regulatory and Safety
North American ITE
• UL 60950-1 2nd edition Listed Device (U.S.)
• CSA 22.2 No. 60950-1 2nd edition 2014(Canada)
• Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)
• CDRH Letter of Approval (US FDA Approval)
• CDRH Letter of Approval (US FDA Approval)
European ITE
• EN 60950-1 2nd Ed.
• EN 62368-1
• EN 60825-1 Class 1 (Lasers Safety)
• 2014/35/EU Low Voltage Directive
International ITE
• CB Report & Certificate per IEC 60950-1 + National
Dierences
• IEC 62368-1
• AS/NZS 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North American EMC Certifications
• FCC CFR 47 part 15 Class A (USA)
• ICES-003 Class A (Canada)
European EMC Certifications
• EN 55032 Class A
• EN 55024
• EN 55011
• EN 61000-3-2 (Harmonics)
• EN 61000-3-3 (Flicker)
• EN 300 386 vl.6.1 (EMC Telecommunications)
• 2014/30/EU EMC Directive
International EMC Certifications
• CISPR 32 Class A (International Emissions)
• AS/NZS CISPR32
• CISPR 24 Class A (International Immunity)
• IEC 61000-4-2/EN 61000-4-2 Electrostatic Discharge,
6kV Contact, 8kV Air, Criteria B
• IEC 61000-4-3/EN 61000-4-3 Radiated Immunity l0V/m,
Criteria A
• IEC 61000-4-4/EN 61000-4-4 Transient Burst, 1 kV, Criteria A
• IEC 61000-4-5/EN 61000-4-5 Surge, 1 kV L-L, 2 kV G, Level 3,
Criteria B
• IEC 61000-4-6/EN 61000-4-6 Conducted Immunity, 0.15-80
MHz, l0Vrms, 80%AM (lkHz), Criteria A
• IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25
periods, Criteria C
Country Specific Certifications
• VCCI Class A (Japan Emissions)
• ACMA RCM (Australia Emissions)
• CCC Mark
• KCC Mark, EMC Approval (Korea)
• BSMI (Taiwan)
• Anatel (Brazil)