Quick Reference

V400 Virtual Port Extender
Quick Reference
Follow these steps to get your port extender up and
running.
For complete installation instructions see the ExtremeSwitching and
Summit Switches: Hardware Installation Guide at
www.extremenetworks.com/documentation
Tools You’ll Need
Appropriate grounded power receptacles
located within 1.8 m (6 ft.)
A readily accessible device for disconnecting
power, such as a breaker or master switch
Network cabling within reach
At least of 7.6 cm (3.0 in.) on all sides, for
proper ventilation
Temperature between 0°C (32°F) and 45°C
(113°F) for PoE models or between 0°C
(32°F) and 50°C (122°F) for non-PoE models, with fluctuations of less
than 10°C (18°F) per hour
If the port extender appears to be damaged, contact Extreme
Networks. See “Getting Help” for more information.
Extreme Networks does not include power input cords with this product.
To purchase the correct power cord for your country, refer to
www.extremenetworks.com/product/powercords/. This page lists
details for purchasing a power cord from Extreme Networks or from
your local supplier.
1 #1 Phillips screwdriver
(magnetic screwdriver recommended)
3 ESD (Electrostatic Discharge) wrist
strap
2 Flat-head screwdriver
1
Prepare the Site
The installation site must meet the following requirements:
2
Unpack the Box
Remove the packing material. Break the tape seal on the
non-conductive bag and remove the port extender.
1 V400 Virtual Port Extender 3 Mounting brackets
2 Screws for attaching brackets
4
Rubber feet
The V400 Virtual Port Extender can be mounted flush with the rack
posts or mid-mounted.
To attach the port extender to a rack:
1 Attach the mounting brackets to the sides of the port extender using
four screws (included) for each bracket.
2 Align the holes in the brackets with the rack post holes.
3 Secure the port extender to each post with rack-mounting screws.
1 Attach the ESD wrist strap to your wrist and connect the metal end
to an appropriate ground point on the rack.
2 Remove the transceiver from its packaging.
3 If applicable, remove the protective dust cover from the connector.
4 Hold the transceiver so that the connector will seat properly.
5 Carefully align the transceiver with the port slot.
6 Push the transceiver into the port slot until it clicks into place.
3
Install the Equipment
You can install the V400 Virtual Port Extender in a
standard 19-inch equipment rack.
4
Install Transceivers
(Optional) Transceivers can send and receive data over
optical fiber rather than through electrical wires. This
installation procedure applies to all transceivers.
Note: Transceivers are Class 1 laser devices.
Connecting to Standard AC Power
1 Connect an AC power cord to the AC power input socket on the port
extender and to an AC power outlet.
2 When power is connected, verify that the PWR LED on the port
extender turns green. If the PWR LED does not turn green, refer to
the Hardware Installation Guide for troubleshooting information.
Connecting to a Redundant Power Supply
To attach your port extender (PoE models only) to the VX-RPS-1000
redundant power supply:
1 Install the power supply according to the instructions that are
included with it.
2 Connect a power cable (included with the power supply) to the
output socket on the power supply and the RPS input connector on
the rear of the port extender.
3 Connect the power supply to an AC power source, using the
instructions that are included with the power supply.
4 When power is connected, verify that the PWR LED on the port
extender turns green.
1 Enable VPEX on a supported switch. Refer to the ExtremeXOS User
Guide for details.
2 Attach the port extender to a 10 Gb SFP+ port on the switch.
Safety Notices
5
Connect Power
The V400 Virtual Port Extender can receive electrical
power from a standard AC power outlet. Optionally, PoE
models can receive power from an external VX-RPS-1000
redundant power supply (part no. 18202).
Installing the system as described in this guide meets the protective
earth grounding requirements of the National Electrical Code (NEC),
UL/CSA/IEC/EN 60950-1 standards. However, in some cases, it may
be necessary to use an alternative grounding method. In these
cases, a 14 AWG wire can be connected between the grounding lug
on the chassis and a nearby building ground point.
6
Activate the Port Extender
To activate your port extender:
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Risques d’électrocution: Seul un personnel qualifié doit effectuer
les procédures d'installation.
Warning: Extreme Networks power supplies do not have switches for turning
the unit on and off. Before servicing, disconnect all power cords to remove
power from the device. Make sure that these connections are easily accessible.
Avertissement: Extreme Networks alimentations ne sont pas des interrupteurs
pour allumer l'appareil et en dehors. Avant l'entretien, débranchez tous les
cordons d'alimentation pour couper l'alimentation de l'appareil. Assurez-vous
que ces connexions sont facilement accessibles.
Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each
power supply connection.
Avertissement: Un disjoncteur cotée dédiée évalué à 15A doit être utilisée pour
chaque connexion d'alimentation.
Caution: Before mounting the device, ensure that the rack can support it
without compromising stability. Otherwise, personal injury and/or equipment
damage may result.
Caution: Follow appropriate ESD procedures when unpacking and handling
the device. These include unpacking the device in an ESD-safe environment
and wearing appropriate ESD protective gear, such as ESD-safe footwear and
ESD wrist straps where appropriate.
Caution: Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Warning: LASER RADIATION
Fiber-optic ports use Class 1 lasers.
DO NOT EXPOSE USERS OF TELESCOPIC OPTICS
Do not use optical instruments to view the laser output. The use of optical
instruments to view laser output increases eye hazard. Use only UL/CSA,
IEC/EN60825-1/-2 recognized pluggable modules.
Avertissement: RAYONNEMENT LASER
Ports de fibres optiques utilisent des lasers de classe 1.
NE PAS exposer les utilisateurs de télescopique OPTIQUE.
Ne pas utiliser d'instruments optiques pour voir la sortie du laser. L'utilisation
de instruments optiques pour afficher la sortie laser augmente les risques
oculaires. Utilisez uniquement UL / CSA, IEC/EN60825-1 /-2 reconnu modules
enfichables.
Hardware Components
Figure 1 V400 Virtual Port Extender: Front Panel (48 Port Model Shown)
Figure 2 V400 Virtual Port Extender: Rear Panel
For component details, see the Hardware Installation Guide.
Operating Conditions
Operating Temperature:
0°C (32°F) to 45°C (113°F) for PoE models
0°C (32°F) to 50°C (122°F) for non-PoE models
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
5% to 95% (non-condensing)
Operating Altitude:
0 to 3,000 meters
Interfaces
Each V400 Virtual Port Extender has a console port and a USB port. The
following table lists the specific interfaces for each port extender.
Power Specifications
Redundant Power Supply (Optional)
1 10/100/1000BASE-T ports 3 10Gb SFP+ ports
2 Console/management port 4
USB port
1
Grounding lug 3 AC power input connector
2
RPS connector (some models)
V400-24t-10GE2
(Part no. 18101)
V400 base unit with 24 10/100/1000BASE-T ports,
2 1000/10GBaseX unpopulated SFP+ ports, fixed power
supply and fan
V400-24p-10GE2
(Part no. 18102)
V400 base unit with 24 10/100/1000BASE-T PoE+
ports, 2 1000/10GBaseX unpopulated SFP+ ports, fixed
power supply and fan
V400-48t-10GE4
(Part no. 18103)
V400 base unit with 48 10/100/1000BASE-T ports,
4 1000/10GBaseX unpopulated SFP+ ports, fixed power
supply and fan
V400-48p-10GE4
(Part no. 18104)
V400 base unit with 48 10/100/1000BASE-T PoE+
ports, 4 1000/10GBaseX unpopulated SFP+ ports, fixed
power supply and fan
V400-24t-10GE2
(Part no. 18101)
AC Input: 100-240 VAC, 50/60Hz, 0.6 A max
V400-24p-10GE2
(Part no. 18102)
AC Input: 100-240 VAC, 50/60Hz, 5.4-2.2 A max
DC RPS Input: 54 VDC, 18.52 A max
PoE ports load to 382W for AC input only.
PoE ports load to 720W for DC input only.
PoE ports load to 720W for AC+DC input.
V400-48t-10GE4
(Part no. 18103)
AC Input: 100-240VAC, 50/60Hz, 1.0 A max
V400-48p-10GE4
(Part no. 18104)
AC Input: 100-240 VAC, 50/60Hz, 12.0-6.0 A max
DC RPS Input: 54 VDC, 18.52 A max
PoE ports load to 740W for AC input only.
PoE ports load to 900W for DC input only.
PoE ports load to 1440W for AC+DC input.
For V400 PoE Models
VX-RPS-1000
(Part no. 18202)
AC Input: 100-120 VAC, 50-60Hz, 12A max or
AC Input: 200-240 VAC, 50-60Hz, 6A max
DC Output: +54.0 VDC, 18.52A max