Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.1 Release Notes
76
PD4-882862442,
PD4-767856469
After running the save command and rebooting a switch with a VLAN translation
configuration, duplicate packets are sent to member VLANs from the translation VLAN.
PD4-899492655,
PD4-505794657
Repeatedly running multiple commands from a telnet session causes memory depletion in
the exsh process.
PD4-929585868,
PD4-507170288
Traffic received on an STP/EAPS blocked port is being sent to the CPU if the source MAC
address of the incoming packet matches the MAC address of the DUT system.
PD4-803700570,
PD4-795451285
After disabling flooding for broadcast traffic, the broadcast traffic originated from the
switch is not flooded out.
PD4-774654053 A 10GE module fails silently followed by a silent MSM failover.
PD4-780725598,
PD4-779916611
When a static entry is added to a configured domain, the entry is also added to another
domain.
PD4-817416641,
PD4-541064246
When configuring rate-limiting on a switch, the max-burst-size value is not reset after
reconfiguring the switch.
PD4-817416749,
PD4-504813986
In a DNS server, if the RADIUS server IP address is specified as CNAME, that is, Alias, a
switch is not able to resolve the IP address correctly.
PD4-932027220,
PD4-698458401
Every 300 seconds, kill entries installed by PIM are not removed from hardware,
therefore, traffic for those entries does not hit the CPU.
PD4-855250053,
PD4-843000831
The counter for the show traffic queue statistics command is displayed as
"multiple" when ingress ports are on different I/O modules but all ports have the same
egress ports.
PD4-953613971,
PD4-944885511
Receiving LACP PDUs that are larger than 500 causes the LACP process to die with a
signal 11 error.
PD4-962772378,
PD4-924242747
The FDB process may die with signal 11 when the show fdb statistics command
is executed.
PD4-974227479,
PD4-767595507
The log filter is not shown in the output of the show upm profile <profile-name>
command.
PD4-843337987,
PD4-748079627
The debug log <Info:thttpd.info> 13 line feeds removed is not necessary
and is shown when configuring a switch with HTTPS.
PD4-985272501,
PD4-943063565
The cliMaster fails with a signal 6 error when running the show configuration pim
command while PIM is configured with a static CRP.
PD4-980404139,
PD4-899333484
The thttpd process CPU utilization increases and HTTP/HTTPS is not accessible if sock/
stress attack is performed on an HTTPS port. This issue persists indefinitely even after a
sock/stress attack is removed.
PD4-985606480,
PD4-791833227
If an IPv6 tunnel is configured, adding a static route causes the Route Table Manager to
crash with a signal 11 error.
PD4-826754349,
PD4-581257425
An error occurs when loading an ExtremeXOS 12.1 or earlier software configuration file if
the banner configuration contains a new line character.
PD4-806088040,
PD4-684400473
A switch does not generate high CPU utilization log messages after executing the clear
cpu-utilization command, even if process CPU utilization goes above the threshold value.
PD4-993453673,
PD4-983772991
The ifMauDefaultType MIB is populated with the wrong value when a switch is running
ExtremeXOS 12.3.3 software.
PD4-1023187137,
PD4-968719352
When running the terminate process exsshd forceful command while an SSH
session is in progress, the SSH session does not shut down even if it is no longer seen in
the output of the show session command. When restarting the SSH session using the
start process exsshd command, the switch appears to hang while waiting for the
ongoing SSH session to be terminated.
PD4-1005347431,
PD4-990080561
In CLI non-persistent mode, modifying a port in a VLAN from an untagged port to a
tagged port deletes the port from that VLAN.
BlackDiamond 8800 Series Switch
Table 41: Platform-Specific and Feature PDs (Continued)
PD Number Description