Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.1 Release Notes
72
PD4-901778542 The command mrinfo <neighbor ipaddress> from <source ipaddress> is
not displaying the entire interface when the source IP address is changed.
PD4-1084698943,
PD4-977234454
Configuring UPM profiles to include the show port info detail command results
in the show profile history command output showing the status as failed.
BlackDiamond 8800 Series Switch
PD4-449743037 Group entries are not timing out on Multicast VLAN Registration (MVR) and non-MVR
VLANs even though snooping is disabled on the non-MVR VLAN.
BlackDiamond 12800 Switch
PD4-750488331 When a BlackDiamond 12800 series switch with 4,000 BVLANs and 2,000 SVLANs
configured and IGMP snooping disabled, the switch crashes when enabling sharing with
LACP on BVLAN ports. This configuration may also cause an MSM to go into a failed
state.
PD3-205380274 sFlow is not working on ports that are included in BVLANs, SVLANs, and occasionally
vMANs. sFlow can be enabled and configured for ports in BVLANs, SVLANs, and vMANs,
but nothing is sent to the sFlow collector.
BlackDiamond 20800 Series Switch
PD4-1168490821 While perfroming an install firmware using ExtremeXOS 12.4.1 from CR 17 (ExtremeXOS
12.2.2.11-patch1-3 firmware), the fan tray upgrade fails. Reinstall the firmware to
upgrade the fan tray to CR 23 with ExtremeXOS 12.4.1.The fan tray fails with the
following error message:
tftp: server error: (0) Wrong TFTP State
TFTP FAILED: TRAY 1, Fantray Secondary image
Fantray firmware installation failed for Tray-1
Error: Failed to install image -
PD4-667561942 The command output for the show fdb hardware command does not include the
blackhole MAC address.
PD4-757563008 After hot swapping an MM-A, the output for the show power budget command shows
the wrong power information.
PD4-717942168 FDB entries are not learned for L2 broadcast traffic after an MM failover.
PD4-861903871 After loading image ExtremeXOS 12.3.2.5 on a BlackDIamond 20808 switch, the show
log command output shows the following error:
<Erro:HAL.Sys.Error> MM-B: Unable to get odometer for power
supply 5
The same log error is displayed when a failover occurs on MM-A.
PD4-851358292 During a firmware upgrade, the "watchdog expiration warnings" and "kernel thread stuck"
messages may appear on an MM console.
PD4-843054490 Fans are going in to a failed/empty state and I/O modules are powered off after upgrading
firmware on a BlackDiamond 20808 using the force option.
PD4-845017407 The following error is seen when running the install firmware command on a GM-40XB
module in a BlackDiamond 20808 switch:
<Erro:HAL.Card.PowerStateError> MM-A: A request to power down
slot 8 failed - returning a completion code of -1.
Summit Family Switches
PD3-77711011 The word “slot” should not be included in the output of the show inline-power
stats command.
PD3-131375426 Configuring autopolarity does not work on the combo ports on the Summit family
switches.
Table 40: Platform-Specific and Feature PDs (Continued)
PD Number Description