Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.1 Release Notes
66
PD4-587169451 Running the install firmware command may generate numerous error messages in
the Event Management System (EMS) logs. These messages do not impact system
performance.
<Erro:HAL.Sys.BackupPFCFailed> MM-A: Backup Power Fan Controller
(#2) has failed
<Erro:EPM.Upgrade.Fail> MM-A: Upgrade failed, script: install
bootrom failed
<Erro:HAL.Sys.GetPFCMastershipFailed> MM-A: Failed to get Power
Fan Controller Mastership for slot #17
<Erro:HAL.Sys.OtherPFCFailed> MM-B: Power Fan Controller in slot
17 has failed to communicate with EXOS
<Erro:HAL.Sys.SetBackupPFCToMaster> MM-B: An error happened and
is now setting the backup Power Fan Controller #2 to be the
master Power Fan Controller
<Erro:HAL.Sys.MasterPFCFailed> MM-B: Master Power and Fan
Controller (#1) has failed
<Crit:HAL.Fabric.Critical> MM-A: pioennerBringDownFE200 Bringing
Down FE200 on XBAR 1 as the command EXTRUC_FE_READ_CMD Failed,
Reason: UCPIPE_ERROR
<Erro:HAL.Sys.Error> MM-A: Slot XBAR1: 23918 FE 0 read 0xb50
Summit Family Switches
PD3-127401831 On a Summit X250e platform with 128 VRRP instances that are advertised for 100
milliseconds, the feature "don't preempt" is not working properly.
PD4-1102582531 In a PVLAN, network login MAC-based authentication does not work in ExtremeXOS
12.4.0.19.
PD4-427423116 When a dot1x client is authenticated at multiple VLANs, the output of the show
netlogin port command shows the client is sometimes authenticated at the local
server and other times at a RADIUS server.
Note: This occurs when dot1x and MAC authentication are enabled on the port.
PD4-1101069206 When configuring 2,000 VPWS instances, only 1,023 VPWS instances are created.
PD3-71725881 When configuring an optional name for the time zone/DST, the time zone name truncates
at seven characters. The system default is six characters.
PD4-1142692318 On Summit X480 switches, L3 multicast traffic sent from a service VLAN/vMAN to VPLS
is not received at the VPLS peer.
Workaround: Two modes of operation are supported on ports that are configured as part of
a VPLS service VLAN.
Using the first mode, the following configuration is set for all VLANs on the port (VPLS
service VLANs and non-VPLS service VLANs):
1 IGMP snooping is configured as disabled. The default is enabled.
2 No IP address is configured.
Using the second mode, the following configuration is set:
1 Run the configure igmp snooping filters per-VLAN command. The default
is per-port.
2 If an IP address is configured for a VPLS service VLAN, run the configure
ipmcforwarding to-cpu off port <port> command. The default is auto.
PD4-448681226 The show l2stats command does not count ARP packets to the CPU, even though the
packet goes to the CPU.
PD4-489142320 One Gigabit ports set to auto on flap twice during a switch reboot.
PD4-489359602 Conflicting Link Fault Signal (LFS) alarms are shown when disabling local ports.
Table 39: Platform-Specific and Feature PDs (Continued)
PD Number Description