PD4-847978862 A monitor port does not come up after enabling a port after a DUT is rebooted with a
disabled monitor port. The following error is displayed while rebooting:
MM-A: voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
08/15/2009 16:47:02.47 < Erro:HAL.Card.Error > MM-A:
voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
PD4-841530197 The install firmware command displays a lot of errors in the log and the HAL CPU
goes to 99% capacity.
FE200 on XBAR 3 as the command EXTRUC_FE_WRITE_CMD Failed,
Reason: UCPIPE_ERROR
08/10/2009 02:58:43.26 MM-A: Error Register Write
ExtremeFE200Writ
eUc Offset: a10 Value ffffffff for Fabric Slot: 3
08/10/2009 02:56:32.29 MM-A: Slot-8 FAILED (3) Error Generic
Error(-1) from HAL on CardExec POWER_OFF(10) for slot 8
08/10/2009 02:56:32.29 MM-A
PD4-803757411 Configuring a meter on a BlackDiamond 20808 switch to limit broadcast or multicast
traffic (rate-limit flood-traffic) is not possible without an HQoS license.
PD4-748388236 Egress rate shaping does not work after running the save and reboot commands if an
egress port is not specified. Configured egress rate-shaping does not work on a newly
inserted I/O module if an egress port is not specified.
Workaround: Unconfigure the ACL and re-apply the same ACL.
PD4-715473099 The multicast traffic receive rate for 10,000 multicast groups takes an excessive amount
of processing time.
PD4-756263261 The show fabric command in an ExtremeXOS environment shows the fabric
information is XFM-2.
PD4-728354005 On a BlackDiamond 20808 switch, running the show tech-support command when I/
O modules or fabric slots are in the process of booting, or are otherwise not operational,
may cause sys-health-check output to display fabric link faults, when there are
actually none. This is a transient state. Once the modules are operational, only actual
fabric link faults are displayed in the command output.
PD4-756213981 BlackDiamond 20808 multicast rate-limit supports a minimum 10 Mbps.
PD4-603229266 A slot reboots when load sharing is disabled and MVR is disabled and re-enabled.