Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.1 Release Notes
61
PD3-104885349 When a shared link comes up, temporary traffic loss may occur until FDB entries are
aged. Aging occurs by default every five minutes.
Workaround: To reduce traffic loss, reduce the default age time.
PD3-132775269 Telnet sessions between two switches using two windows causes one session to hang if
both sessions are edited but only one session is saved.
PD3-28378521 Enabling load sharing on a port that is being mirrored causes the mirroring to stop.
BlackDiamond 8800 Series Switch
PD3-190363671 The following error message is displayed while hot swapping PSUs:
Unable to read PSU-2 FRU data. Try reinserting PSU more quickly.
Workaround: Remove and reinsert the PSU quickly. Insert the PSU in a single, continuous
motion with a firm push.
BlackDiamond 10808 Switch
PD3-28320363 In IPv6, the encapsulate value is “next header,” which is not currently a valid attribute.
PD3-124124316 The following error messages are shown in the log when running 50,000 unicast routes
with ECMP enabled:
02/05/2007 15:38:37.89 <Warn:HAL.Sys.Warning> MSM-A: hal: Reached
maximum otp index allocation
02/05/2007 15:38:37.56 <Warn:HAL.Sys.Warning> MSM-A: Previous
message repeated 999 additional times in the last 1 second(s)
PD3-68165111 Various memory locations that are part of the forwarding and routing tables are parity
protected on BlackDiamond 10808 switches. The functionality should be turned on so
that faults are detectable.
PD4-318846862 L3 multicast traffic in a VPLS vMAN is forwarded twice when the LSP is changed to port
sharing and is then changed back.
PD3-54870537,
PD3-45729158
Under the following circumstances, EAPS control packets received on the wrong VLAN
may be treated and processed.
1 Create a EAPS ring with three or more switches with a BlackDiamond 10808 as one of
the transit switches, directly connect to the master with load sharing enabled.
2 Enable load sharing on the primary port of the master switch (the master port should
be higher than the group port so that the configuration master and current master are
different in load sharing).
3 Disable load sharing on the BlackDiamond 10808.
4 Show EAPS on the master switch; the domain state will be complete.
5 The control packets are transmitted on the current master and the BlackDiamond
10808 will receive the packets on the port that is not part of the EAPS VLAN.
PD3-202184409 Adding/deleting a LAG s
PD3-133427241 When an OSPF external filter is configured to deny routes, not all routes are being
filtered.
PD3-204793983 The egress rate-limit shown in the command output of the show port utilization
command is not correct.
BlackDiamond 12800 Series Switch
PD4-1195687987 The BGP process crashes with signal 6 while trying to delete a VLAN from a user created
VR in MPLS-VR.
Workaround: Disable BGP prior to deleting the VLAN and enable graceful restart on BGP.
Table 39: Platform-Specific and Feature PDs (Continued)
PD Number Description