Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
95
PD4-1252711676 IRS traffic is getting dropped when an ACL is configured with a traffic queue specifying
the egress port. Works fine if port is not specified.
PD4-1050879321 The message log fills up the following hellocount Info messages during firmware upgrade
from CR 21 (EXOS 12.3.2.5) to CR 23 (EXOS 12.4.1). This action can eliminate any
important message in the log buffer. 12/16/2009 20:56:17.15 <Info:HAL.Sys.Info> MM-A:
XBAR ucPipeCallBackFn slot 21. helloCount 9. 12/16/2009 20:56:17.15
<Info:HAL.Sys.Info> MM-A: XBAR ucPipeCallBackFn slot 20. helloCount 9. 12/16/2009
20:56:17.15 <Info:HAL.Sys.Info> MM-A: XBAR ucPipeCallBackFn slot 19. helloCount 9.
12/16/2009 20:56:17.15 <Info:HAL.Sys.Info> MM-A: IO ucPipeCallBackFn slot 8.
helloCount 9.
PD4-1308580041 Diffserv examination and diffserv replacement do not respond after performing a save
and reboot on a BlackDiamond 20800 series switch.
PD4-1207376781 Paging does not work for CustomerVlanConfig and BVlanConfig.
PD4-1081408709 Packets in lower priority queues are getting dropped even though the sum of the streams
bandwidth is less than the queue meter value.
PD4-722565502 Hot insert of a PSU, or reseating an AC plug on a PSU, causes the following error
messages on a BlackDiamond 20800 series switch and causes the show power
budget command to read the wrong value for the PSU.
* BD-20804.25 #
########### CRITICAL ERROR
devmgr: dmps.c:563: power_add(): REASON: total->volt[i] == p2-
>volt[i]
* BD-20804.26 # sh power bud
Watts
PS State at 48V
--------------------------------------------
1 Powered On 2340.00
2 Powered On 3480.00
3 Powered On 6960.00
PD4-1235317131 Running the show access-list counter command on a BlackDiamond 20800 series switch
causes a buffer leak, which results in a slot failure and conduit error.
PD4-920567621 While creating 100,000 static FDB entries, the MM console stops responding after
creating a few MACs.
PD4-1083141408 A hard failover between two MMs (hotswapping a master MM) causes a PSU to go into
failed state, even though both PSUs look operational.
PD4-1052907851 Removing and adding VLANs into EAPS-Domain causes a fabric error:
PSUCTRL-2 :
FABRIC-1 : 806001-00-06 09106-80092 Rev 6.0 uC: 2.4 F-1: 1.0 F-
2: 1.0
FABRIC-2 : 806001-00-06 09066-80136 Rev 6.0 uC: 2.4 F-1: 1.0 F-
2: 1.0
FABRIC-3 : 806001-00-05 09066-80073 Rev 5.0 uC: 2.4 F-1: 1.0 F-
2: 1.0
FABRIC-4 : 806001-00-05 09106-80155 Rev 5.0 uC: 2.4 F-1: 1.0 F-
2: 1.0
FABRIC-5 : Rev 0.0
Summit Family Switches
PD4-1023729033 A Summit family switch is not sending the SNMP traps “extremeFanFailed” and
“extremeFanOK.”
PD4-1478418711 When the reboot command is run on a stack master with a confirmation to save the
configuration, the HAL process may not respond, which causes the EPM process to kill
the HAL process. Subsequently, the master node reboots. This issue may also been seen
on a SummitStack.
Table 54: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description