PD4-1318549914 In the ACL policy file for SNMP, the “source-address” field is the only supported match
condition. Any other match conditions are ignored.
PD4-1289042980 In Web Netlogin, logout popup window is displayed momentarily then quickly disappears
and logout page has incorrect info when logout-privilege is disabled
PD4-1253879412 When creating VPLS instances, the service VLAN name is not shown. SmartTraps are
received, but Ridgeline SA is unable to collect the VLAN data.
PD4-1265355788 VLAN mirroring cannot mirror packets that are ingressing a LAG port when the master
port link is disabled.
PD4-1272649253 The invalid syntax keyword tag_name is added when configuring a syslog target.
PD4-1185907951 Disabling learning on VLAN results in LACP packets being dropped
PD4-1211850839
When disconnecting a network login authenticated client who is connected through a
dynamically created network login VLAN, process mcmgr crashes and generates the follow-
ing log message:
***** Process mcmgr pid: 518 died with signal: 11
BlackDiamond 8800 Series Switch
PD4-1322479483 In SNMP MIB, ModuleconfiguredType and ModuleInsertedType values for 10G4Xc and
10G8Xc I/O cards are incorrect.
PD4-1203047506 On BlackDiamond 8800 series switches, the inline power state remains delivering on the
G48P and G48Pe modules after a powered device is removed from a port.
PD4-1190894931 Traffic ingressing a G48T, G48P, G24X, G8X, or 10G4X module that egresses a load
sharing member port on a different I/O module is dropped when an 8900-MSM128
module is in use. In the case of a stack that contains an original series Summit X450
and X650, traffic ingressing the Summit X450 that egresses a load sharing member port
on a Summit X650 switch is also dropped. Only certain LAG groups are affected, most
notably, the first LAG group is not affected.
PD4-1239769161 When running pings for an L3 interface, ping packets are dropped when IP forwarding is
enabled on a BlackDiamond 8800 series switch.
PD4-1202084496
When configuring PIM Sparse mode on a BlackDiamond 8800 original series switch, a
memory leak is detected. Workaround: disable multicast route compression by running the
configure forwarding ipmc compression off command.
BlackDiamond 10800 Switch
PD4-1272649937 ESMI related warning messages are seen in the output of the show log command
whenever an SSL certificate with a key length of 4,096 is created or the HTTPD process
is restarted.
PD4-1197058460 Fans on a BlackDiamond 10800 switch may run at a higher RPM, causing unacceptable
noise levels.
BlackDiamond 12800 Series Switch
PD4-1250201281 A hardware error may occur on a BlackDiamond 12800 series switch resulting in a
misread on the backplane SerDes FPGAs. This misread is interpreted by the system-
health-check as an error, which in turn may cause an I/O module or MSM to be taken
offline.
BlackDiamond 20800 Series Switch
PD4-1402199417 The customer had an XM-8XB in IOB slot-2 and only one XFM-1 in fabric slot-1.
Runtime diags shows the following error:
Slotnum 2 DiagResult timestamp Thu Jun 24 02:06:50 2010 Test
Temperature(s) = 33C 33C 35C 34C Diag Version=1.0.1.7. EXOS
Version=12.4.1.7 S/N=09366-80141
------------------------------------------------ System Test
FABRIC Connectivity: Device 3 Link 19 Failed
Table 54: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description