Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
93
Resolved Issues in ExtremeXOS 12.4.2
The following issues were resolved in ExtremeXOS 12.4.2. ExtremeXOS 12.4 includes all fixes up to and
including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.5, ExtremeXOS 12.2.2,
and ExtremeXOS 12.3.6. For information on those fixes, see the release notes for the specific release.
EAPS
PD4-1482379553,
PD4-1248684161
The ExtremeXOS CLI does not prevent a user from enabling BOOTP on an EAPS
control VLAN.
PD4-1386102367 When running ExtremeXOS PIM-SM in a multi-access case (that is, an EAPS ring):
A downstream router should not send periodic (S, G) prunes.
Over-riding a PIM-JOIN message is delayed when multiple (S,G) prunes are received.
ScreenPlay
PD4-1502591163,
PD4-1523521971
A switch may hang on executing the restart process thttpd command when the CPU
utilization for thttpd reaches 99.9%.
SNMP
PD4-1504020368,
PD4-796910727
Using SNMPv3, a user does not receive a warning message when trying to log on to a
switch using the wrong password.
PD4-1459378855,
PD4-1440591951
The extremePowerSupplyStatus SNMP variable values in the EXTREME-SYSTEM-MIB
are not sufficient to represent the various states of a power supply.
STP
PD4-1493262831,
PD4-1197366638
Ports become active and start forwarding traffic before STP is operational when
rebooting.
VRRP
PD4-1460240047,
PD4-1355839871
A switch should not allow a user to telnet to a VRRP VIP if the source address is in a
different network from the VRRP VIP network.
Table 54: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1095776451 An Extreme switch is unable to make a connection if the management IP is in VR
Default.
Workaround: XML notifications only work on the Management VR.
PD4-1110970277 Nettools crashes with signal 11 when a continuous ping is configured for more than 10
SSH or telnet sessions.
PD4-1423144102 Switch reboots after 130 failed login attempts
PD4-1376627795 The Polycom SPIP 331 phone exceeds the IEEE class power limit for a class 1 device.
This feature enhancement removes the ExtremeXOS restriction based on the IEEE Class
Power Limit and uses the Class Power Limit as informational only.
PD4-1344772450 Session variables are not saved across MSM or Stack failover. User needs to manually
execute the script to populate the session variables after failover.
PD4-1383408085 SysRq keys must be disabled by default
Table 53: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description