Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
90
Resolved Issues in ExtremeXOS 12.4.2-patch1-3
The following issues were resolved in ExtremeXOS 12.4.2-patch1-3. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.5, ExtremeXOS 12.2.2, and ExtremeXOS 12.3.6. For information on those fixes, see the
release notes for the specific release.
PD4-1531283743 After setting dot1dStp SNMP OIDs, the switch experiences an STP process crash with
signal 11.
Table 52: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1562364701 When the udp-profile is used to forward traffic to a destination-ipaddress, a memory leak
is observed in ip_dst_cache.
PD4-1422715218 When a switch receives a telnet break command, the telnetd/exsh process crashes
with signal 3.
PD4-1289183953 HAL process dies with signal 6 when issuing the debug hal show ipv4mc gaddr
command with an invalid IP address.
PD4-1509628441 When sending VPLS traffic for approximately 100 E-LANs, traffic for one of the E-LANs
may get lost.
PD4-1523638899,
PD4-1142795450
The ExtremeXOS CLI may allow load sharing groups to be formed using ports with
different link speeds.
Workaround: Do not change the speed settings before enabling LACP on the remote
switch.
PD4-334620931 During an MSM or MM failover, an MSDP peer incorrectly prints debug messages in the
log as warning messages.
BlackDiamond 8800 Series Switch
PD4-1535593829 An untagged packet that is size 1,518 and ingressing an 8900-G48X-xl module is getting
slowpath L3 forwarded.
PD4-1548201973 The following error message is seen every seven hours when there is a data loop:
<Erro:Kern.Card.Error> Slot-4: b44: eth1: transmit timed out, resetting
PD4-1507934901,
PD4-1141415551
Software redundant ports become active for a short period of time after performing a
save and rebooting the switch.
PD4-1521499552 L2 traffic ingressing a 10G8X-xl I/O module for a MAC that is learned in another slot
(G48Tc) is being dropped in some cases.
PD4-1476359639 A link flap is causing VPWS traffic to stop forwarding.
BlackDiamond 20800 Series Switch
PD4-1522821191 A BlackDiamond 20800 series switch crashes when a new VLAN translation member
VLAN is added. The system appears to run out of multicast/flooding PSI resources.
PD4-1508905375 A BlackDiamond 20800 series switch is unable to ping and learn ARP traffic in a vMAN
and VLAN interconnected network setup.
Table 51: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description