Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
83
Resolved Issues in ExtremeXOS 12.4.3-patch1-5
The following issues were resolved in ExtremeXOS 12.4.3-patch1-5. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.5, ExtremeXOS 12.2.2, and ExtremeXOS 12.3.6. For information on those fixes, see the
release notes for the specific release.
Table 47: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1823016071,
PD4-1090889907
High CPU utilization messages are not logged while SNMP traps are sent.
PD4-1867797741 An LX mini-GBIC is incorrectly detected as an FX/LX mini-GBIC. This applies only to
Summit family switches and BlackDiamond 20800 series switches.
PD4-1815606257,
PD4-896535258
When a banner configuration file stored in a Windows environment is loaded, the banner
configuration is not restored properly.
Note: After unconfiguring a switch, the system banner message cannot be restored using a
saved configuration.
Workaround: Reconfigure the banner message.
PD4-1821932411 The following directories are viewable in a browser window when Web HTTP is enabled:
• /scripts
• /images
• /assets
• /com
PD4-1851014168,
PD4-1323337297
A switch will experience memory depletion due to HAL process when sending L2 traffic to
a PVLAN with continuous SA increment.
PD4-1813267523,
PD4-1239811496
Deleting a VLAN does not cleanup route entries learned by RIP through the VLAN.
PD4-1847511220 When running the SSH process (exsshd), CPU usage is excessive and some SSH
sessions are not cleared.
BlackDiamond 8800 Series Switch
PD4-1828332180,
PD4-1147104931
A BlackDiamond 8800 series switch takes more than 30 minutes to boot up with VLAN
aggregation configured.
PD4-1854613879 On a BlackDiamond 8800 series switch, multicast packets are sent directly to the CPU
instead of being forwarded in hardware.
BlackDiamond 20800 Series Switch
PD4-1536990491 When a BlackDiamond 20800 series switch is an EAPS master, port QP1 increments
instead of port QP8.
Summit Family Switches
PD4-1506829269 On Summit family switches, ethernet loopback tests fail when running extended
diagnostics without an active management port.
PD4-1254695518 When deleting a port from an ELRP configured VLAN, the switch displays errors after
running the save and reboot commands.
PD4-1813046514 DHCP snooping log messages display the incorrect port information when a LAG violation
occurs.