Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
81
Resolved Issues in ExtremeXOS 12.4.4
The following issues were resolved in ExtremeXOS 12.4.4. ExtremeXOS 12.4 includes all fixes up to and
including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.5, ExtremeXOS 12.2.2,
and ExtremeXOS 12.3.6. For information on those fixes, see the release notes for the specific release.
BlackDiamond 8800 Series Switch
PD4-1936494545 After running an MSM failover, the MAC addresses for the IP DAD entries are flushed and
not displayed. This does not affect IP DAD functionality.
PD4-1688446379 FDB entries learned via LAG are not included in the output of the show fdb stats
ports all command.
PD4-1984639923,
PD4-1983542737
VLAN switch fabric hardware programming fails to reprogram a trunk to the correct unit on
an I/O module after an unexpected failover occurs.
Summit Family Switches
PD4-1985805842,
PD4-1983309381
Summit X460 and X480 switches fail to display the switch serial number due to EEPROM
corruption.
PD4-1661214241 A Summit family switch does not send a PSU related SNMP trap when a secondary PSU
fails.
PD4-1776441950 Software-controlled redundant ports may cause loops if a port is configured for redundancy
after it is associated with an existing VLAN.
SummitStack
PD4-1981255870,
PD4-1229634794
LACP packets are corrupted if the master port is mirrored on a SummitStack.
Table 46: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1943788332,
PD4-1920719829
CLEAR-Flow rules are not getting hit when a match condition is configured for byte-
count.
PD4-1466022175 When an SNMP query is issued for non-existent IPv4 routes, the RtMgr process crashes
with signal 11.
PD4-1956914209,
PD4-1937052478
Telnet access profiles are blocking all IPv6 telnet connections.
PD4-1957143087,
PD4-1034683284
You cannot load a script using a flow-redirect configuration when a VLAN is down.
PD4-1887144111,
PD4-1155806118
When an unknown vendor ID is sent in a RADIUS accept packet, the log message does
not print the unknown vendor ID.
PD4-1887057001 Running the configure flow-redirect <redirectname> no-active/health-
check command resets a configured VR to a VR-Default.
Workaround: Run the configure flow-redirect <redirectname> vr command
after configuring the configure flow-redirect <redirectname> no-active/
health-check command.
PD4-1835754679,
PD4-1177495965
XML API allows a user to create several VLANs using the same VLAN tag.
Table 45: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description