Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
80
Resolved Issues in ExtremeXOS 12.4.4-patch1-2
The following issues were resolved in ExtremeXOS 12.4.4-patch1-2. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.6, ExtremeXOS 12.2.2-patch1-12, and ExtremeXOS 12.3.6. For information on those
fixes, see the release notes for the specific release.
Summit Family Switches
PD4-1507934866 The file generated by the show tech all logto file command contains a broken
configuration line.
DHCP
PD4-1372389708 Running the upload ip-security dhcp-bindings command fails with the
following error:
Object dhcpBindingsUpload does not support method set.
IGMP
PD4-2051283879,
PD4-1374138231
The configured IGMP query interval timer does not take effect immediately. The timer
takes effect only after the current interval expires.
OSPF
PD4-1493257018 The forwarding address in an external LSA should not be set for an interface that is
configured as passive.
Spanning Tree Protocol
PD4-1780972901 Renaming a VLAN and deleting the STP domain to which it has an auto-bind relation,
and auto-binding it to a new STP domain displays the following error:
Error: Cannot enable auto-bind for vlan v2 to STP domain s2, it
is the carrier vlan of STP domain s1
Table 45: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1963836921 Direct routes exported to RIPng are not removed from the routing table after disabling
RIPng. Also, the route count of routes exported to RIPng are shown incorrectly when
running the show iproute ipv6 command.
PD4-1409846531 The icmp-type match condition for ICMPv6 is not supported on Summit family and
BlackDiamond 8800 series switches.
PD4-1933787279 The Node Manager process consumes excessive CPU usage on a backup MSM when the
system uptime reaches 994 days.
PD4-1981933632,
PD4-1374774241
The SNMP OID extremeCurrentTemperature does not return the current temperature of a
switch. This is also seen when accessing the switch using ScreenPlay.
PD4-1981365201,
PD4-1870786111
Running the disable netlogin port <slot:port> command while the slot is down
causes the switch to drop the packets received on that port in hardware if the ethernet-
source-address is not learned. This affects EAPSv1 control packets because the ethernet-
source-address in the EAPSv1 control packets is a special MAC and will never be learned.
Table 44: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description