Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
66
PD4-757707981 Proxy ARP does not work in a PVLAN.
PD4-526514731 On a BlackDiamond 20800 series switch, the system experiences a random packet drop
from the MM to the packet processor health check loopback interface.
PD4-730820249 If a route prefix in a BlackDiamond 20800 series switch is more than 24, only 100,000
routes are stored in the hardware. For the route prefixes less than 24, then 512,000
routes are stored in the hardware.
PD4-734160880,
PD4-697230006
Extreme Networks does not support the same (S,G) stream entering a switch through
multiple constituent VLANs of a private VLAN or VLAN aggregation. If a source moves
from one constituent VLAN to another, run the clear igmp snooping command.
PD4-1048824150 Deleting meters reports an error after an access list is configured and unconfigured
multiple times.
Workaround: Configure another meter.
PD4-1066604251 In dual MM systems, whenever a meter deletion results in a timeout, the show meter
command output still shows the meter, even though the error meter could not be
found is displayed.
Workaround: Create and use another meter.
PD4-1064653511 The error ........***** Process hal pid: 474 died with signal:11 is
displayed on an active MM when 1,000 policy files are configured on multiple egress
ports.
Workaround: Configurations exceeding the scaling limit are not supported.
PD4-1064653532 When configuring an access list with traffic queues, with a 10G port as one of the egress
port, traffic is lost when the corresponding 10G I/O module is hot swapped.
Workaround: Disable and re-enable the I/O module.
PD4-1056439342 I/O modules reboot when egress rate shaping is configured above 1,000 traffic queues
with all egress ports.
Workaround: Configure egress rate shaping with the proper scaling limits.
PD4-861903959 When the backup MM is not yet synced (because of run msm-failover or running
diagnostics) and one performs an MM-failover, the command is accepted, however, both
MMs will then reboot.
Workaround: Make sure that run-time diagnostics command checks that both MMs
are in sync before running the diagnostics.
PD4-847978862 A monitor port does not come up after enabling a port after a DUT is rebooted with a
disabled monitor port. The following error is displayed while rebooting:
MM-A: voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
08/15/2009 16:47:02.47 < Erro:HAL.Card.Error > MM-A:
voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
PD4-803757411 Configuring a meter on a BlackDiamond 20808 switch to limit broadcast or multicast
traffic (rate-limit flood-traffic) is not possible without an HQoS license.
PD4-748388236 Egress rate shaping does not work after running the save and reboot commands if an
egress port is not specified. Configured egress rate-shaping does not work on a newly
inserted I/O module if an egress port is not specified.
Workaround: Unconfigure the ACL and re-apply the same ACL.
PD4-715473099 The multicast traffic receive rate for 10,000 multicast groups takes an excessive amount
of processing time.
Table 39: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description