Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
65
PD4-1026932011 Hot swapping an XFM module may cause an odometer reading error. ExtremeXOS will
not be able to read the odometer reading.
FABRIC-2 information:
State: Operational
PartInfo: XFM-2 10076-80022 806019-00-05
Revision: 5.0
FailureCode: 0
Odometer:
Temperature: 40.0 deg C
Status: FABRIC Mode
PD4-973196600 The following error or warning messages are seen after installing firmware from CR 21
(ExtremeXOS 12.3.2.5) to CR 22 (ExtremeXOS 12.4.1):
* (debug) BD-20808.8 # show log sev err < Erro:Kern.Error > MM-A:
ide0: unexpected interrupt, status=0xd0, count=1
<Erro:Kern.Error> MM-B: ide0: unexpected interrupt, status=0xd0,
count=1
<Erro:HAL.Card.Error> MM-A: PHD EEPROM READ ERROR..SLOT=8,
ADDR=167
<Erro:HAL.Card.Error> MM-A: Previous message repeated 2
additional times in the last 60 second(s)
< Crit:HAL.Fabric.Critical> MM-A: pioneerBringDownFE200 Bringing
Down FE200 on XBAR 2 as the command EXTRUC_FE_MCAST_WRITE_CMD
Failed, Reason: UCPIPE_TIMEOUT
<Erro:HAL.Card.PowerStateError> MM-A: A request to power down
slot 8 failed - returning a completion code of -1 .
<Erro:HAL.Card.Error> MM-A: PHD EEPROM READ ERROR..SLOT=5,
ADDR=167
<Erro:HAL.Card.Error> MM-A: Previous message repeated 2
additional times in the last 59 second(s)
<Crit:DM.Critical> MM-B: Slot-5 FAILED (6) IO Slot5 Micro
controller was reset. Attempt to recover
<Crit:DM.Critical> MM-A: Slot-4 FAILED (6) IO Slot4 Micro
controller was reset. Attempt to recover
<Crit:cm.file.openErr> MM-B: Failed to open file "/config/
primary.cfg": No such file or directory
PD4-1135195907 With 4,000 VPLS instances, L2 unicast traffic recovers 8 to 10 minutes after disabling
and enabling VPLS or MPLS traffic in a three node configuration.
PD4-465744039 ACL counters are not hitting the IGMP packets.
PD4-506754505 When creating a dynamic egress ACL to deny all traffic, the traffic still hits the ARP reply
counter but not denying the packets.
PD4-450852442 When configuring an ACL and using the keyword denyAll in the create access-
list command, the action is not stopping the ARP reply packets.
PD4-614541490 VPLS traffic stops after configuring MAC limit-learning.
PD4-720906222 Performing a save and reboot on a DUT with 5,000 dynamic ACLs causes one module to
go into a failed state while the remaining modules stay in ACL sync even after one hour.
PD4-690958111 After running the unconfigure switch all command, an I/O module may stick in
the booting state, resulting in the switch continually rebooting.
PD4-631700490 When PIM and PIM snooping are enabled on the same VLAN, and if that VLAN happens
to be a PIM egress VLAN, traffic forwarding does not happen on the VLAN.
PD4-854675001,
PD4-860561781
A BlackDiamond 20808 switch with a single MM running ExtremeXOS 12.3.2 software
fails to upgrade during a firmware upgrade process. It also fails during the firmware
downgrade process. You may need to try and install the firmware multiple times.
PD4-552222911 DUT is hanging with a busy message (dots) after configuring 7,250 ingress dynamic
ACLs with conduit errors.
Table 39: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description