PD4-1736472663 If an FX/LX port is disabled when a slot is down, once the slot is operational again,
running the enable port command may not restore the traffic for some of the FX/LX
ports.
PD4-1736184348 When a configuration has an FX/FX port disabled, after running the save and reboot
commands, enabling the port may not properly bring the link up.
PD4-1736184341 On a BlackDiamond 12800 series switch, when a port that contains an FX/LX SFP is
disabled, the switch reports the port as "active" even though the link goes down correctly
on the remote end.
PD4-722565430 IPv6 ACL address masks are not working correctly after rebooting a switch.
PD4-737811617 Creating a blackhole FDB entry on a BlackDiamond 12800 series switch still forwards
traffic from a BlackDiamond 20808 to a BlackDiamond 12800.
Workaround: Create blackhole entries for the same MAC on each of the subscriber
VLANs.
PD4-742951283 An I/O slot fails due to a Tx data memory overflow and generates the following error
message:
<Erro:HAL.Card.Error> MSM-A: skylerHC-1184: skyler12 on slot 1 (4
errors):TX Data Memory Overflow: reg 0x32 value 0x01000001 wanted
(0x00000000) got (0x01000000)
PD4-740255437 Policy files are not refreshed when generating 30,000 rules.
PD4-285686375 After upgrading to the latest ExtremeXOS 12.1.2. image, the following EEPROM error
message appears in the log:
MSM-A: MSM-B card eeprom checksum failed. 0xb97 != 0xb96
PD3-125288233 MSTP fails to converge when a vMAN Ethernet type is set to 0x8100 on a BlackDiamond
12800 series switch.
PD3-192175421 The following error message is displayed when installing a policy file with more than
4,096 rules:
Error: Unable to bind traffic queue tq4095 to port 1:1.
PD3-187808062 A BlackDiamond 12800 series switch does not show a warning message on the console
for down revision MSM and I/O modules after initialization.
PD3-86738591 Traffic queue statistics are incorrect when a BlackDiamond 12800 series switch is
configured to work in H-QoS mode. Statistics counters are accurate when the switch is
configured in the PRI mode.
PD3-118914021 When an OSPF neighbor is configured between two LSRs and MPLS, and an LDP
session is configured between them, the ABR router advertises a default route to the
internal router. The default route is not mapped to a label in the internal router because
the ABR does not advertise the label
BlackDiamond 20800 Series Switch
PD4-1254536303 In the output of the CLI command show traffic queue egress-port 2:1,
"onlyIn" statistics are not getting updated based on the traffic passed.
PD4-730221901 Refreshing an ACL on an MM-B while running an MSM failover on MM-A causes MSM-A
to lose the ACL configuration on MSM-A.
PD4-646084932 An FDB entry for a non-isolated VLAN is not show in the output of the show fdb
command after disabling and enabling an I/O module.
PD4-733230780 MAC security does not work on a PVLAN.
PD4-749280880 Installing firmware fails and displays the following message:
tftp: server says: Wrong TFTP State
Table 39: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description