Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
103
PD4-936088746,
PD4-791316018
When using SCP to download an image, the image fails to install on the backup MSM
and the following error is displayed:
Installing to MSM-BError: Failed to install image - tar: /
scratch/bd8800-12.1.3.14.xos: No such file or directory.
PD4-862132071,
PD4-238870391
When STP notifies EAPS that it has flushed an FDB table, EAPS no longer performs an
additional FDB flush of the local switch. The additional flush was not necessary and had
a side effect of inadvertently unauthenticating netlogin clients on the local switch.
PD4-855783094,
PD4-769156523,
PD4-1026560731
The message MSM-A: Error while saving "psePort": is displayed when a
save command is executed after reconfiguring a slot as a G48te2 (PoE) to G48te2
module.
PD4-973716614,
PD4-975082490
EDP information is not displayed when a port is not a member of a VLAN or is tagged.
Workaround: Add port 1:1 (untagged) to the VLAN default.
BlackDiamond 10808 Switch
PD4-828655386,
PD4-630233676
After performing a hitless upgrade, the show version command output still shows the
old master filename, not the new image. However, the show switch command output
shows the correct image.
BlackDiamond 12800 Series Switch
PD3-125511903 A system failure occurs with a signal 10 error when performing a run msm-failover
immediately after the backup MSM is in-sync
PD4-616376481,
PD4-901339862
The following error message is displayed during NetloginMac_V2 regression after
rebooting a switch with the save option set to yes:
<Erro:HAL.Card.Error> MSM-A: Unable to remove broadcast MAC entry
for VLAN/VMAN while changing tag from 1 to 3999
PD4-1079033931,
PD4-751999119
When configuring HQoS, traffic goes to the correct traffic queue but is not limited by the
meter threshold rate.
PD4-735984501 DUT crashes while configuring static routes via 6in4 tunnels.
PD4-856182552,
PD4-698686480
Even after a vMAN ethertype is changed using the CLI, packets are egressing out the
service vMAN using an older vMAN ethertype.
PD4-882862525,
PD4-723664780
After performing a hitless upgrade from ExtremeXOS 12.0 or later to ExtremeXOS 12.1
or later, packets are sent to the CPU for L3 switching, even though hardware entries
exist for the destination IP.
PD4-828265583,
PD4-569838439
Packets that need to be L2 switched are not egressing if the packets hit the IPv4 ACL
containing a redirect action.
This fix requires a regular upgrade on a BlackDiamond 12804 switch. It will not work if
you attempt a hitless upgrade on the BlackDiamond 12804 switch.
PD4-882862632,
PD4-852419857
Creating and deleting HQoS queues on a BlackDiamond 12808 results in the following
error:
Error: Timeout awaiting Traffic Queue operation.
PD4-973716520,
PD4-964896284
When PIM Sparse mode is configured on a BlackDiamond 8800 series switch with c-
series I/O modules, a memory leak is detected.
PD4-979176325,
PD4-832095668
The ACL match condition ports ingress <port-no> causes incoming packets to be
forwarded to all ports in a VLAN as per the VLAN tag for incoming packets, even though
the ingress port is not part of that VLAN.
BlackDiamond 20800 Series Switch
PD4-913402141,
PD4-1034364517
Process XMLD crashes if multiple "OpenSession" XML requests are sent continuously.
Table 57: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description