Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.4 Release Notes
101
PD4-825283681,
PD4-699307521
When running the show ports stack-ports rxerrors command, the "RX Over"
count continuously increments, even without user traffic.
PD4-828265339,
PD4-537092174
Enabling diffserv examination on Summit family or BlackDiamond 88000 series switches
causes dot1p replacement of 802.1q tagged packets.
PD4-843338040,
PD4-796910653
The switch stops forwarding traffic after disabling remote mirroring.
Workaround: Delete the ports from the data VLAN and add it back to the VLAN.
PD4-882862442,
PD4-767856469
After running the save command and rebooting a switch with a VLAN translation
configuration, duplicate packets are sent to member VLANs from the translation VLAN.
PD4-899492655,
PD4-505794657
Repeatedly running multiple commands from a telnet session causes memory depletion
in the exsh process.
PD4-929585868,
PD4-507170288
Traffic received on an STP/EAPS blocked port is being sent to the CPU if the source
MAC address of the incoming packet matches the MAC address of the DUT system.
PD4-803700570,
PD4-795451285
After disabling flooding for broadcast traffic, the broadcast traffic originated from the
switch is not flooded out.
PD4-774654053 A 10GE module fails silently followed by a silent MSM failover.
PD4-780725598,
PD4-779916611
When a static entry is added to a configured domain, the entry is also added to another
domain.
PD4-817416641,
PD4-541064246
When configuring rate-limiting on a switch, the max-burst-size value is not reset after
reconfiguring the switch.
PD4-817416749,
PD4-504813986
In a DNS server, if the RADIUS server IP address is specified as CNAME, that is, Alias,
a switch is not able to resolve the IP address correctly.
PD4-932027220,
PD4-698458401
Every 300 seconds, kill entries installed by PIM are not removed from hardware,
therefore, traffic for those entries does not hit the CPU.
PD4-855250053,
PD4-843000831
The counter for the show traffic queue statistics command is displayed as
"multiple" when ingress ports are on different I/O modules but all ports have the same
egress ports.
PD4-953613971,
PD4-944885511
Receiving LACP PDUs that are larger than 500 causes the LACP process to die with a
signal 11 error.
PD4-962772378,
PD4-924242747
The FDB process may die with signal 11 when the show fdb statistics command
is executed.
PD4-974227479,
PD4-767595507
The log filter is not shown in the output of the show upm profile <profile-name>
command.
PD4-843337987,
PD4-748079627
The debug log <Info:thttpd.info> 13 line feeds removed is not necessary
and is shown when configuring a switch with HTTPS.
PD4-985272501,
PD4-943063565
The cliMaster fails with a signal 6 error when running the show configuration pim
command while PIM is configured with a static CRP.
PD4-980404139,
PD4-899333484
The thttpd process CPU utilization increases and HTTP/HTTPS is not accessible if sock/
stress attack is performed on an HTTPS port. This issue persists indefinitely even after a
sock/stress attack is removed.
PD4-985606480,
PD4-791833227
If an IPv6 tunnel is configured, adding a static route causes the Route Table Manager to
crash with a signal 11 error.
PD4-826754349,
PD4-581257425
An error occurs when loading an ExtremeXOS 12.1 or earlier software configuration file if
the banner configuration contains a new line character.
PD4-806088040,
PD4-684400473
A switch does not generate high CPU utilization log messages after executing the clear
cpu-utilization command, even if process CPU utilization goes above the threshold value.
PD4-993453673,
PD4-983772991
The ifMauDefaultType MIB is populated with the wrong value when a switch is running
ExtremeXOS 12.3.3 software.
Table 57: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description