User`s manual

Anritsu User’s Manual - Page
9 of 13.
EXAMPLE:
MEASUREMENT RUN: RUN1
Field Label Measurement Data Name
Type
STRING STRING
Range
MEASUREMENT
RUN:
1 to 128 alphanumeric
characters
Required
Field
Yes Yes
Example
MEASUREMENT
RUN:
RUN1
Measurement Data Comments [Line 5]
This line of the Header identifies any notes or user comments associated with the
measurement data. It consists of the label “NOTES:” followed by a string field separated
by a tab. For the Anritsu HHSA WVC Logfile, this line should appear similar to the
following:
EXAMPLE:
NOTES: Transmitter on third floor, southwest corner
Field Label Measurement Data Notes
Type
STRING STRING
Range
NOTES: 1 to 128 characters
Required Field
Yes Yes
Example
NOTES: Measuring third and fourth
floors
Number of Base Station Association Markers [Line 6]
This line of the Header is used to indicate how many markers are used to
associate base stations, if any. That is, if a spectrum analyzer sweep is being made and
the associations are being made using markers, the sixth line will tell how many markers
are being used. If a power monitor measurement is being made, or if a spectrum analyzer
sweep is being made using average signal strength for associations, then there are no
markers and thus no associations.