Title Line [Line 1]
This next line of the WVC Logfile is the Title Line, and consists of a logfile
description, a date of logfile creation, and the drawing name the file was originally
created in or exported from, separated by a tab.
EXAMPLE:
Extreme Networks Summit WMScanner Measurement Logfile, v.12.0.2 10/19/09 Default_Final.dwg
Logfile Description Date of Creation
Type
STRING DATE
Month/Day/Year in the
form MM/DD/YY.
Range
1 – 128 characters Month: 01 to 12
Day: 01 to 31
Year: 00 to 99
Required
Field
Yes No
Example
Extreme Networks,
Summit WMScanner
Measurement Logfile,
v.12.0.2
10/29/09
Logfile Type [Line 2]
The next line of the Header identifies the type of measurement device of the
logfile. This line of the logfile header combined with the version number above, enables
Summit WMScanner to recognize the format of the remainder of the logfile. For the
WVC logfile created by an Anritsu HHSA, the type of logfile is specified to be
“SITEMASTER”. It consists of the label “TYPE:” followed by a string field, separated
by a tab. For the Anritsu HHSA, this line must appear exactly as follows:
EXAMPLE:
TYPE: SITEMASTER
Field
Label
Type of Logfile
Type
STRING STRING
Range
TYPE: SITEMASTER
Required
Field
Yes Yes
Example
TYPE: SITEMASTER
Measurement Mode [Line 3]
The next line of the Header identifies what mode data was collected using:
Spectrum Analyzer or Power Monitor.